Edit these specs to order a different model. Not all combinations are
valid. Options compatible with previous selections will be in bold.
FLUIDWELL F018 Intrinsically safe - Flow rate Monitor / Totalizer | with linearization | pulse/alarm and analog outputs | HART communication | Ambient temperature: -40°C to +80°C (-40°F to 176°F).
Brand :
Stock Status :
Contact us for delivery
Brand :
Stock Status :
Out of Stock
Part Number : F018
Featuring linearization and continuous flow rate monitoring, the F018 is a local indicator/transmitter. It shows the non-resettable accumulating total, resettable total, and real linearized flow rate. Globally, the F-Series is recognized for its assortment of easily navigable indications. It becomes even better with the F018. You may easily communicate with intelligent "DD enabled host" systems by using the HART communication protocol.
Fifteen linearization points with their corresponding frequencies or values can be entered in addition to the average K-Factor or Span. Even for very low frequency applications, the device will interpolate between these locations, considerably improving accuracy in any flow range. Both the signal outputs and the visible data are impacted by this linearization.
Specification
Features
Catalog
Specifications
Details
Input
Signal Inputs Flowmeter Inputs Pulse type inputs: Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
Power Supply
Long life Lithium battery. 16 – 30V DC. Basic: 8 - 30V DC. Analog output loop powered. Sensor Supply : 1.2 / 3.2 or 8.2V DC.
Flow rate, total, accumulated total, alarm values, and alarm messages are all displayed on the display.
Large digit selection available for total or flow rate.
clearly displays the alarm messages.
In the event of a flow rate alert, the red flashing LED illumination has adjustable intensity.
The flow curve was linearized at fifteen points using interpolation.
It is possible to enter the low and high flow rate alarm values.
Retransmission of pulses received from the source, for example, in order to amplify and square sinewave or coil signals or for calibration.
Seven 17mm (0.67") or 8mm (0.31") numbers indicate the flow rate.
Total: seven resettable digits measuring 17 mm (0.67").
Total accumulated: eleven 8mm (0.31") non-resetable digits.
distinct technical units for total and flow rate.
Scaled pulse output with the sum accumulated reflected in it.
In accordance with ATEX, IECEx, FM, and CSA C-US, intrinsic safety.
FLUIDWELL F010 Intrinsically safe - Flow rate Indicator | Input Signal (0)4 – 20mA | Temperatures between -40°C up to +80°C (-40°F up to 176°F).
Part Number : F010
Part Number : F010 FLUIDWELL F010 Intrinsically safe - Flow rate Indicator | Input Signal (0)4 – 20mA | Temperatures between -40°C up to +80°C (-40°F up to 176°F).
FLUIDWELL F011 Intrinsically safe - Totalizer | with resettable total and non-resettable accumulated total | Temperatures between -40°C up to +80°C (-40°F up to 176°F).
Part Number : F011
Part Number : F011 FLUIDWELL F011 Intrinsically safe - Totalizer | with resettable total and non-resettable accumulated total | Temperatures between -40°C up to +80°C (-40°F up to 176°F).
FLUIDWELL F012 Intrinsically safe - Flow rate Indicator / Totalizer | Displays flow rate and total simultaneously | Input Signal (0)4 – 20mA | Temperatures between -40°C up to +80°C (-40°F up to 176°F).
Part Number : F012
FLUIDWELL D010 DIN Panel mount - Flow rate Indicator | Input Signal (0)4 – 20mA | Ambient temperature -40°C up to +80°C (-40°F up to 176°F).
Part Number : D010
FLUIDWELL D011 DIN Panel mount - Totalizer | with resettable total and non-resettable accumulated total | Ambient temperature: -40°C to +80°C (-40°F to 176°F).
Part Number : D011
FLUIDWELL D012 DIN Panel mount - Flow rate Indicator / Totalizer | Displays flow rate and total simultaneously | Ambient temperature -40°C up to +80°C (-40°F up to 176°F).
Part Number : D012
FLUIDWELL B - Basic Flow rate Indicator / Totalizer
Part Number : B-Basic
FLUIDWELL F014 Intrinsically safe - Flow rate Indicator / Totalizer | Input (0)4 – 20mA | Temperatures between -40°C up to +80°C (-40°F up to 176°F).
Part Number : F014
FLUIDWELL F110 Intrinsically safe - Flow rate Indicator / Totalizer | with Modbus communication | Analog and pulse outputs | Input (0)4 – 20mA.
Part Number : F110
FLUIDLINE F111 Intrinsically safe - Dual input Flow rate Indicator / Totalizer | Temperatures between -40°C up to +80°C (-40°F up to 176°F).
Part Number : F111
FLUIDWELL F115 Intrinsically safe - Bi-directional Flow rate Indicator / Totalizer | with analog, pulse signal and flow direction outputs
Part Number : F115
FLUIDWELL D014 DIN Panel mount - Flow rate Indicator / Totalizer | with pulse signal output | Ambient temperature -40°C up to +80°C (-40°F up to 176°F).
Part Number : D014
FLUIDWELL E110 Explosion proof - Flow Logger / Totalizer | with analog and pulse signal outputs
Part Number : E110
FLUIDWELL E115 Explosion proof - Bi-directional Flow rate Indicator / Totalizer | with analog, pulse and flow direction outputs
Part Number : E115
FLUIDWELL B-SMART | Basic - Flow rate Indicator / Totalizer | with pulse and analog output | Loop powered 4 - 20mA output