Edit these specs to order a different model. Not all combinations are
valid. Options compatible with previous selections will be in bold.
FLUIDWELL F126-EG | Intrinsically safe - Flow Computer for gas | with temperature and pressure compensation for corrected volume | Ambient temperature: -40°C to +80°C (-40°F to 176°F).
Brand :
Stock Status :
Contact us for delivery
Brand :
Stock Status :
Out of Stock
Part Number : F126-EG
The F126-EG flow computer was designed to compute corrected gas volume under typical circumstances. By measuring the uncorrected volumetric flow, actual line temperature, and pressure—all of which are processed using equations kept in the flow computer—one can determine the corrected volumetric flow. One can adjust a compressibility factor to approximate the behavior of a real gas. It is possible to define the reference conditions as desired (e.g., 1.013 bar and 15°C or 60°F).
The display indicates the real line temperature and pressure in addition to the corrected flow rate, total, and accumulated total. Nm³ and other on-screen engineering units are readily configurable from a wide range of options.
Specification
Features
Catalog
Specifications
Details
Input
Flowmeter Inputs Pulse type inputs: Reed-switch, open collector, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal. Temperature Inputs PT100 - 2 or 3 wire PRTD sensor. Pressure Inputs (0)4 – 20mA.
computes the total, accumulated total, and adjusted flow rate.
shows the temperature and line pressure as it is.
An analog signal that is output that shows the flow rate correction.
simultaneously shows the total, the flow rate, and any additional accumulated total.
Counting in seven 8mm (0.31") increments.
Total: seven resettable digits measuring 17 mm (0.67").
Total accumulated: eleven 8mm (0.31") non-resetable digits.
Six 17mm (0.67"). temperature digits.
Six 17mm (0.67") digits of pressure.
On the display are engineering units for temperature, pressure, flow rate, and total.
LED backlighting.
intrinsic safety as defined by IECEx and ATEX.
Enclosures made of GRP, aluminum, or premium stainless steel.
EEPROM memory is used for automatic setting and running total backups.
From -40°C to +80°C (40°F to 176°F) is the ambient temperature.
FLUIDWELL F010 Intrinsically safe - Flow rate Indicator | Input Signal (0)4 – 20mA | Temperatures between -40°C up to +80°C (-40°F up to 176°F).
Part Number : F010
Part Number : F010 FLUIDWELL F010 Intrinsically safe - Flow rate Indicator | Input Signal (0)4 – 20mA | Temperatures between -40°C up to +80°C (-40°F up to 176°F).
FLUIDWELL F011 Intrinsically safe - Totalizer | with resettable total and non-resettable accumulated total | Temperatures between -40°C up to +80°C (-40°F up to 176°F).
Part Number : F011
Part Number : F011 FLUIDWELL F011 Intrinsically safe - Totalizer | with resettable total and non-resettable accumulated total | Temperatures between -40°C up to +80°C (-40°F up to 176°F).
FLUIDWELL F012 Intrinsically safe - Flow rate Indicator / Totalizer | Displays flow rate and total simultaneously | Input Signal (0)4 – 20mA | Temperatures between -40°C up to +80°C (-40°F up to 176°F).
Part Number : F012
FLUIDWELL D010 DIN Panel mount - Flow rate Indicator | Input Signal (0)4 – 20mA | Ambient temperature -40°C up to +80°C (-40°F up to 176°F).
Part Number : D010
FLUIDWELL D011 DIN Panel mount - Totalizer | with resettable total and non-resettable accumulated total | Ambient temperature: -40°C to +80°C (-40°F to 176°F).
Part Number : D011
FLUIDWELL D012 DIN Panel mount - Flow rate Indicator / Totalizer | Displays flow rate and total simultaneously | Ambient temperature -40°C up to +80°C (-40°F up to 176°F).
Part Number : D012
FLUIDWELL B - Basic Flow rate Indicator / Totalizer
Part Number : B-Basic
FLUIDWELL F014 Intrinsically safe - Flow rate Indicator / Totalizer | Input (0)4 – 20mA | Temperatures between -40°C up to +80°C (-40°F up to 176°F).
Part Number : F014
FLUIDWELL F110 Intrinsically safe - Flow rate Indicator / Totalizer | with Modbus communication | Analog and pulse outputs | Input (0)4 – 20mA.
Part Number : F110
FLUIDLINE F111 Intrinsically safe - Dual input Flow rate Indicator / Totalizer | Temperatures between -40°C up to +80°C (-40°F up to 176°F).
Part Number : F111
FLUIDWELL F115 Intrinsically safe - Bi-directional Flow rate Indicator / Totalizer | with analog, pulse signal and flow direction outputs
Part Number : F115
FLUIDWELL D014 DIN Panel mount - Flow rate Indicator / Totalizer | with pulse signal output | Ambient temperature -40°C up to +80°C (-40°F up to 176°F).
Part Number : D014
FLUIDWELL E110 Explosion proof - Flow Logger / Totalizer | with analog and pulse signal outputs
Part Number : E110
FLUIDWELL E115 Explosion proof - Bi-directional Flow rate Indicator / Totalizer | with analog, pulse and flow direction outputs
Part Number : E115
FLUIDWELL B-SMART | Basic - Flow rate Indicator / Totalizer | with pulse and analog output | Loop powered 4 - 20mA output