Dwyer Instruments CDT-2E44 | Carbon Dioxide/Temperature | Wall Mount | Universal current/voltage output | European Housing

Brand : Image Brand
Stock Status : Contact us for delivery
Brand : Image Brand
Stock Status : Out of Stock

Part Number : CDT-2E44

The Series CDT, Model CDT-2E44 is a Carbon Dioxide and Temperature Transmitter that precisely measures the CO2 concentration and temperature in interior spaces, helping to save energy. The Series CDT incorporates barometric pressure adjustment to provide even higher precision. To interact with almost any building management controller, customers can choose the transmitter output to be 4-20 mA, 0-5 VDC, or 0-10 VDC using the CO2 universal output. The wall mount variants of the Series CDT can be supplied with an integrated LCD display for applications that need visual indication. An internal dip switch selection can be used to lock out button operation to avoid tampering. The -S option for the Series CDT CO2 transmitters offers the features and characteristics required to meet DSA regulations for CO2 level monitoring in schools. A front-facing LED becomes visible when the CO2 concentration rises above 1100 PPM.

Quantity:
Provide Calibration Services  
  • Specification
  • Features
  • Catalog
Product Name Type Range Accuracy Manufacturer Power Maximum operating temperature Response Time POWER CONSUMPTION Humidity Output Approvals
Dwyer Instruments CDT-2D40 | Carbon Dioxide Transmitter | Duct mount | 2000 ppm CO2 range | 4 to 20 mA / 0 to (5 or 10) VDC CO2 output Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2D44 | Carbon Dioxide Transmitter | Duct mount | 2000 ppm CO2 range | 4 to 20 mA / 0 to (5 or 10) VDC CO2 output & temperature output Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2D4A | Carbon Dioxide Transmitter | Duct mount | 2000 ppm | CO2 transmitter with current/voltage CO2 outputs and 10K Ohm Type III thermistor temperature output Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2D4B | Carbon Dioxide Transmitter | Duct mount | 2000 ppm | CO2 transmitter with current/voltage CO2 outputs and 10K Ohm Type II thermistor temperature output Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2D4D | Carbon Dioxide Transmitter | Duct mount | 2000 ppm | CO2 transmitter with current/voltage CO2 outputs and PT100 Ohm RTD temperature output Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2D4E | Carbon Dioxide Transmitter | Duct mount | 2000 ppm | CO2 transmitter with current/voltage CO2 outputs and PT1000 RTD temperature output Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2D4F | Carbon Dioxide Transmitter | Duct mount | 2000 ppm | CO2 transmitter with current/voltage CO2 outputs and 20K Ohm thermistor temperature output Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2E40 | Carbon Dioxide | Wall Mount | Universal current/voltage output | European Housing Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2E40-LCD | Carbon Dioxide | Wall Mount | Universal current/voltage output | European Housing | LCD Display Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2E44-LCD | Carbon Dioxide/Temperature | Wall Mount | Universal current/voltage output | European Housing | LCD Display. Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2E4B | Carbon Dioxide/Temperature | Wall Mount | Universal current/voltage output | 10K Type II Thermistor Temperature Output | European Housing. Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2E4E | Carbon Dioxide/Temperature | Wall Mount | Universal current/voltage output | Pt1000 RTD Temperature Output | European Housing. Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2N40 | Carbon Dioxide | Wall Mount | Universal current/voltage output | North American Housing Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2N40-LCD | Carbon Dioxide | Wall Mount | Universal current/voltage output | North American Housing | LCD Display Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2N44 | Carbon Dioxide/Temperature | Wall Mount | Universal current/voltage output | North American Housing Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2N44-LCD | Carbon Dioxide/Temperature | Wall Mount | Universal current/voltage output | North American Housing | LCD Display Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2N4A | Carbon Dioxide/Temperature | Wall Mount | Universal current/voltage output | 10K Type III Thermistor Temperature Output | North American Housing Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2N4A-LCD | Carbon Dioxide/Temperature | Wall Mount | Universal current/voltage output | 10K Type III Thermistor Temperature Output | North American Housing | LCD Display Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2N4B | Carbon Dioxide/Temperature | Wall Mount | Universal current/voltage output | 10K Type II Thermistor Temperature Output | North American Housing Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2N4B-LCD | Carbon Dioxide/Temperature | Wall Mount | Universal current/voltage output | 10K Type II Thermistor Temperature Output | North American Housing | LCD Display Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2N4D | Carbon Dioxide/Temperature | Wall Mount | Universal current/voltage output | Pt100 RTD Temperature Output | North American Housing Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2N4D-LCD | Carbon Dioxide/Temperature | Wall Mount | Universal current/voltage output | Pt100 RTD Temperature Output | North American Housing | LCD Display Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2N4E | Carbon Dioxide/Temperature | Wall Mount | Universal current/voltage output | Pt1000 RTD Temperature Output | North American Housing Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2N4E-LCD | Carbon Dioxide/Temperature | Wall Mount | Universal current/voltage output | Pt1000 RTD Temperature Output | North American Housing | LCD Display Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2N4F | Carbon Dioxide/Temperature | Wall Mount | Universal current/voltage output | 20K Thermistor Temperature Output | North American Housing Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2N4F-LCD | Carbon Dioxide/Temperature | Wall Mount | Universal current/voltage output | 20K Thermistor Temperature Output | North American Housing | LCD Display Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDT-2N4B-RLY | Carbon Dioxide/Temperature | Wall Mount | Universal current/voltage output | 10K Type II Thermistor Temperature Output | North American Housing with relay Carbon Dioxide and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Temperature: 32 to 122°F (0 to 50°C)
CO2: ±40 PPM + 3% of reading (2000 PPM CO2)
± 50 PPM + 5% of reading (5000 PPM CO2)
RH: ±2% (10 to 90% RH) (for units configured with humidity output)
Temperature: ±1°C @ 25°C
Dwyer Instruments 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 2 min for 90% step change Average: 2 w
Peak: 3.75 w
Limits: 0 to 85% (non-condensing) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
Relay: SPST NO rated 2A @ 30 VDC
RTD or thermistor per Resistance vs. Temperature Table (depending on model)
CE
Dwyer Instruments CDTA-2N000 | Carbon Dioxide / Temperature / Humidity Communicating Stat with Set Point and Override | Modbus" and BACnet Output | North American Wall Mount Housing | 2000 PPM Range Communicating Carbon Dioxide Detectors CO2 : 0 to 2000 or 5000 PPM CO 2 (depending on model)
Humidity: 0 to 100% RH
Temperature: 32 to 122°F (0 to 50°C)
CO2 : ±40 PPM ±3% of reading 2000 PPM
±50 PPM + 5% of reading 5000 PPM
RH: ±2% (10 to 90% RH)
Temperature: ±1°C @ 25°C
Dwyer Instruments 10-42 VDC / 10-30 VAC 32 to 122°F (0 to 50°C) CO2: 2 min for 90% step change - Limits: 0 to 85% RH (non-condensing) 2-wire RS-485, Modbus ® RTU or BACnet MS/TP communication protocol BTL, CE
Dwyer Instruments CDTA-2N000-LCD | Carbon Dioxide / Temperature / Humidity Communicating Stat with Set Point and Override | Modbus" and BACnet Output | North American Wall Mount Housing | 2000 PPM Range | LCD Display Communicating Carbon Dioxide Detectors CO2 : 0 to 2000 or 5000 PPM CO 2 (depending on model)
Humidity: 0 to 100% RH
Temperature: 32 to 122°F (0 to 50°C)
CO2 : ±40 PPM ±3% of reading 2000 PPM
±50 PPM + 5% of reading 5000 PPM
RH: ±2% (10 to 90% RH)
Temperature: ±1°C @ 25°C
Dwyer Instruments 10-42 VDC / 10-30 VAC 32 to 122°F (0 to 50°C) CO2: 2 min for 90% step change - Limits: 0 to 85% RH (non-condensing) 2-wire RS-485, Modbus ® RTU or BACnet MS/TP communication protocol BTL, CE
Dwyer Instruments CDTA-5N000 | Carbon Dioxide / Temperature / Humidity Communicating Stat with Set Point and Override | Modbus" and BACnet Output | North American Wall Mount Housing | 5000 PPM Range Communicating Carbon Dioxide Detectors CO2 : 0 to 2000 or 5000 PPM CO 2 (depending on model)
Humidity: 0 to 100% RH
Temperature: 32 to 122°F (0 to 50°C)
CO2 : ±40 PPM ±3% of reading 2000 PPM
±50 PPM + 5% of reading 5000 PPM
RH: ±2% (10 to 90% RH)
Temperature: ±1°C @ 25°C
Dwyer Instruments 10-42 VDC / 10-30 VAC 32 to 122°F (0 to 50°C) CO2: 2 min for 90% step change - Limits: 0 to 85% RH (non-condensing) 2-wire RS-485, Modbus ® RTU or BACnet MS/TP communication protocol BTL, CE
Dwyer Instruments CDTA-5N000-LCD | Carbon Dioxide / Temperature / Humidity Communicating Stat with Set Point and Override | Modbus" and BACnet Output | North American Wall Mount Housing | 5000 PPM Range | LCD Display Communicating Carbon Dioxide Detectors CO2 : 0 to 2000 or 5000 PPM CO 2 (depending on model)
Humidity: 0 to 100% RH
Temperature: 32 to 122°F (0 to 50°C)
CO2 : ±40 PPM ±3% of reading 2000 PPM
±50 PPM + 5% of reading 5000 PPM
RH: ±2% (10 to 90% RH)
Temperature: ±1°C @ 25°C
Dwyer Instruments 10-42 VDC / 10-30 VAC 32 to 122°F (0 to 50°C) CO2: 2 min for 90% step change - Limits: 0 to 85% RH (non-condensing) 2-wire RS-485, Modbus ® RTU or BACnet MS/TP communication protocol BTL, CE
Dwyer Instruments CDTR-2D404 | Carbon Dioxide/RH/Temperature Transmitter | 2000 ppm CO2 range | Duct mount | 4 to 20 mA/0 to (5 or 10) VDC CO2 output | RH outputs & no temperature output Carbon Dioxide, Relative Humidity and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Relative humidity: 0 to 100%
Temperature: 32 to 122°F (0 to 50°C)
±40 PPM + 3% of reading (CO2)
±2% (RH)
Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) 2 minutes for 99% step change Average: 2 watts
Peak: 3.75 watts
Limits: 10 to 95% RH (non-condensing) Current: 4 to 20 mA (max 500 Ω)
Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω)
Relay: SPST NO 2A @ 30 VDC
RTD or thermistor per r-t curves (depending on model)
CE
Dwyer Instruments CDTR-2D4A4 | Carbon Dioxide/RH/Temperature Transmitter | 2000 ppm CO2 range | Duct mount | 4 to 20 mA/0 to (5 or 10) VDC CO2 output | RH outputs & 10 kO Type 3 thermistor temperature output Carbon Dioxide, Relative Humidity and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Relative humidity: 0 to 100%
Temperature: 32 to 122°F (0 to 50°C)
±40 PPM + 3% of reading (CO2)
±2% (RH)
Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) 2 minutes for 99% step change Average: 2 watts
Peak: 3.75 watts
Limits: 10 to 95% RH (non-condensing) - CE
Dwyer Instruments CDTR-2D4B4 | Carbon Dioxide/RH/Temperature Transmitter | 2000 ppm CO2 range | Duct mount | 4 to 20 mA/0 to (5 or 10) VDC CO2 output | RH outputs & 10 kO Type 2 thermistor temperature output Carbon Dioxide, Relative Humidity and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Relative humidity: 0 to 100%
Temperature: 32 to 122°F (0 to 50°C)
±40 PPM + 3% of reading (CO2)
±2% (RH)
Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) 2 minutes for 99% step change Average: 2 watts
Peak: 3.75 watts
Limits: 10 to 95% RH (non-condensing) Current: 4 to 20 mA (max 500 Ω)
Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω)
Relay: SPST NO 2A @ 30 VDC
RTD or thermistor per r-t curves (depending on model)
CE
Dwyer Instruments CDTR-2D4D4 | Carbon Dioxide/RH/Temperature Transmitter | 2000 ppm CO2 range | Duct mount | 4 to 20 mA/0 to (5 or 10) VDC CO2 output | RH outputs & Pt100 O RTD temperature output Carbon Dioxide, Relative Humidity and Temperature Transmitters Duct Air Velocity: 0-4000 FPM (20.32 m/s) ±40 PPM + 3% of reading (CO2)
±2% (RH)
Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) 2 minutes for 99% step change Average: 2 watts
Peak: 3.75 watts
Limits: 10 to 95% RH (non-condensing) Current: 4 to 20 mA (max 500 Ω)
Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω)
Relay: SPST NO 2A @ 30 VDC
RTD or thermistor per r-t curves (depending on model)
Dwyer Instruments CDTR-2D4E4 | Carbon Dioxide/RH/Temperature Transmitter | 2000 ppm CO2 range | Duct mount | 4 to 20 mA/0 to (5 or 10) VDC CO2 output | RH outputs & Pt1000 O RTD temperature output Carbon Dioxide, Relative Humidity and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Relative humidity: 0 to 100%
Temperature: 32 to 122°F (0 to 50°C)
±40 PPM + 3% of reading (CO2)
±2% (RH)
Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) 2 minutes for 99% step change Average: 2 watts
Peak: 3.75 watts
Limits: 10 to 95% RH (non-condensing) Current: 4 to 20 mA (max 500 Ω)
Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω)
Relay: SPST NO 2A @ 30 VDC
RTD or thermistor per r-t curves (depending on model)
CE
Dwyer Instruments CDTR-2E404 | Carbon Dioxide/Humidity | Wall Mount | Universal current/voltage output | European Housing Carbon Dioxide, Relative Humidity and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Relative humidity: 0 to 100%
Temperature: 32 to 122°F (0 to 50°C)
±40 PPM + 3% of reading (CO2)
±2% (RH)
Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) 2 minutes for 99% step change Average: 2 watts
Peak: 3.75 watts
Limits: 10 to 95% RH (non-condensing) Current: 4 to 20 mA (max 500 Ω)
Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω)
Relay: SPST NO 2A @ 30 VDC
RTD or thermistor per r-t curves (depending on model)
CE
Dwyer Instruments CDTR-2E4A4 | Carbon Dioxide/Temperature/Humidity | Wall Mount | Universal current/voltage output | 10 kO Type III Thermistor Temperature Output | European Housing Carbon Dioxide, Relative Humidity and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Relative humidity: 0 to 100%
Temperature: 32 to 122°F (0 to 50°C)
±40 PPM + 3% of reading (CO2)
±2% (RH)
Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) 2 minutes for 99% step change Average: 2 watts
Peak: 3.75 watts
Limits: 10 to 95% RH (non-condensing) Current: 4 to 20 mA (max 500 Ω)
Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω)
Relay: SPST NO 2A @ 30 VDC
RTD or thermistor per r-t curves (depending on model)
CE
Dwyer Instruments CDTR-2E4A4-LCD | Carbon Dioxide/Temperature/Humidity | Wall Mount | Universal current/voltage output | 10 kO Type III Thermistor Temperature Output | European Housing | LCD Display Carbon Dioxide, Relative Humidity and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Relative humidity: 0 to 100%
Temperature: 32 to 122°F (0 to 50°C)
±40 PPM + 3% of reading (CO2)
±2% (RH)
Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) 2 minutes for 99% step change Average: 2 watts
Peak: 3.75 watts
Limits: 10 to 95% RH (non-condensing) Current: 4 to 20 mA (max 500 Ω)
Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω)
Relay: SPST NO 2A @ 30 VDC
RTD or thermistor per r-t curves (depending on model)
CE
Dwyer Instruments CDTR-2E4B4 | Carbon Dioxide/Temperature/Humidity | Wall Mount | Universal current/voltage output | 10 kO Type II Thermistor Temperature Output | European Housing Carbon Dioxide, Relative Humidity and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Relative humidity: 0 to 100%
Temperature: 32 to 122°F (0 to 50°C)
±40 PPM + 3% of reading (CO2)
±2% (RH)
Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) 2 minutes for 99% step change Average: 2 watts
Peak: 3.75 watts
Limits: 10 to 95% RH (non-condensing) Current: 4 to 20 mA (max 500 Ω)
Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω)
Relay: SPST NO 2A @ 30 VDC
RTD or thermistor per r-t curves (depending on model)
CE
Dwyer Instruments CDTV-2D404 | Duct VOC & CO2 transmitter | Universal analog outputs | 2000PPM CO2 | No temperature Carbon Dioxide/Volatile Organic Compound Transmitter CO2: 0 to 2000 or 0 to 5000 ppm (depending on model)
VOC: 0 to 2000 ppm CO2 equivalent
CO2: ±40 ppm ±3% of reading Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) CO2: 2 minutes for 99% step change; VOC: 5 minutes Average: 2 watts
Peak: 3.75 watts
- Current: 0 to 20 mA, 4 to 20 mA, 0 to 10 mA, or 2 to 10 mA (depending on selection jumper, max 500 O)
Voltage: 0 to 10 VDC, 2 to 10 VDC, 0 to 5 VDC, or 1 to 5 VDC (depending on selection jumper, min 500 O)
Relay: SPST NO 2A @ 30 VDC
CE
Dwyer Instruments CDTV-2D4A4 | Duct VOC & CO2 transmitter | Universal analog outputs | 2000PPM CO2 | 10K Ohm Type III temperature sensor Carbon Dioxide/Volatile Organic Compound Transmitter Duct Air Velocity: 0-4000 FPM (20.32 m/s) CO2: ±40 ppm ±3% of reading Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) CO2: 2 minutes for 99% step change; VOC: 5 minutes Average: 2 watts
Peak: 3.75 watts
- Current: 0 to 20 mA, 4 to 20 mA, 0 to 10 mA, or 2 to 10 mA (depending on selection jumper, max 500 O)
Voltage: 0 to 10 VDC, 2 to 10 VDC, 0 to 5 VDC, or 1 to 5 VDC (depending on selection jumper, min 500 O)
Relay: SPST NO 2A @ 30 VDC
CE
Dwyer Instruments CDTV-2D4B4 | Duct VOC & CO2 transmitter | Universal analog outputs | 2000PPM CO2 | 10K Ohm Type II temperature sensor Carbon Dioxide/Volatile Organic Compound Transmitter CO2: 0 to 2000 or 0 to 5000 ppm (depending on model)
VOC: 0 to 2000 ppm CO2 equivalent
CO2: ±40 ppm ±3% of reading Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) CO2: 2 minutes for 99% step change; VOC: 5 minutes Average: 2 watts
Peak: 3.75 watts
- Current: 0 to 20 mA, 4 to 20 mA, 0 to 10 mA, or 2 to 10 mA (depending on selection jumper, max 500 O)
Voltage: 0 to 10 VDC, 2 to 10 VDC, 0 to 5 VDC, or 1 to 5 VDC (depending on selection jumper, min 500 O)
Relay: SPST NO 2A @ 30 VDC
CE
Dwyer Instruments CDTV-2D4D4 | Duct VOC & CO2 transmitter | Universal analog outputs | 2000PPM CO2 | PT100 Ohm RTD temperature sensor Carbon Dioxide/Volatile Organic Compound Transmitter CO2: 0 to 2000 or 0 to 5000 ppm (depending on model)
VOC: 0 to 2000 ppm CO2 equivalent
CO2: ±40 ppm ±3% of reading Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) CO2: 2 minutes for 99% step change; VOC: 5 minutes Average: 2 watts
Peak: 3.75 watts
- Current: 0 to 20 mA, 4 to 20 mA, 0 to 10 mA, or 2 to 10 mA (depending on selection jumper, max 500 O)
Voltage: 0 to 10 VDC, 2 to 10 VDC, 0 to 5 VDC, or 1 to 5 VDC (depending on selection jumper, min 500 O)
Relay: SPST NO 2A @ 30 VDC
CE
Dwyer Instruments CDTR-2N404 | Carbon Dioxide/Humidity | Wall Mount | Universal current/voltage output | North American Housing Carbon Dioxide, Relative Humidity and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Relative humidity: 0 to 100%
Temperature: 32 to 122°F (0 to 50°C)
±40 PPM + 3% of reading (CO2)
±2% (RH)
Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) 2 minutes for 99% step change Average: 2 watts
Peak: 3.75 watts
Limits: 10 to 95% RH (non-condensing) Current: 4 to 20 mA (max 500 Ω)
Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω)
Relay: SPST NO 2A @ 30 VDC
RTD or thermistor per r-t curves (depending on model)
CE
Dwyer Instruments CDTV-2D4E4 | Duct VOC & CO2 transmitter | Universal analog outputs | 2000PPM CO2 | PT1K Ohm RTD temperature sensor Carbon Dioxide/Volatile Organic Compound Transmitter CO2: 0 to 2000 or 0 to 5000 ppm (depending on model)
VOC: 0 to 2000 ppm CO2 equivalent
CO2: ±40 ppm ±3% of reading Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) CO2: 2 minutes for 99% step change; VOC: 5 minutes Average: 2 watts
Peak: 3.75 watts
- Current: 0 to 20 mA, 4 to 20 mA, 0 to 10 mA, or 2 to 10 mA (depending on selection jumper, max 500 O)
Voltage: 0 to 10 VDC, 2 to 10 VDC, 0 to 5 VDC, or 1 to 5 VDC (depending on selection jumper, min 500 O)
Relay: SPST NO 2A @ 30 VDC
CE
Dwyer Instruments CDTV-2D4F4 | Duct VOC & CO2 transmitter | Universal analog outputs | 2000PPM CO2 | 20K Ohm temperature sensor Carbon Dioxide/Volatile Organic Compound Transmitter CO2: 0 to 2000 or 0 to 5000 ppm (depending on model)
VOC: 0 to 2000 ppm CO2 equivalent
CO2: ±40 ppm ±3% of reading Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) CO2: 2 minutes for 99% step change; VOC: 5 minutes Average: 2 watts
Peak: 3.75 watts
- Current: 0 to 20 mA, 4 to 20 mA, 0 to 10 mA, or 2 to 10 mA (depending on selection jumper, max 500 O)
Voltage: 0 to 10 VDC, 2 to 10 VDC, 0 to 5 VDC, or 1 to 5 VDC (depending on selection jumper, min 500 O)
Relay: SPST NO 2A @ 30 VDC
CE
Dwyer Instruments CDTV-2N404 | Wall Voc & CO2 transmitter | Universal analog outputs | 2000 ppm CO2 Carbon Dioxide/Volatile Organic Compound Transmitter CO2: 0 to 2000 or 0 to 5000 ppm (depending on model)
VOC: 0 to 2000 ppm CO2 equivalent
CO2: ±40 ppm ±3% of reading Dwyer Instruments Average: 2 watts
Peak: 3.75 watts
32 to 122°F (0 to 50°C) CO2: 2 minutes for 99% step change; VOC: 5 minutes CO2: Single-beam, dual-wavelength NDIR; VOC: MEMS metal oxide semiconductor - Current: 0 to 20 mA, 4 to 20 mA, 0 to 10 mA, or 2 to 10 mA (depending on selection jumper, max 500 O)
Voltage: 0 to 10 VDC, 2 to 10 VDC, 0 to 5 VDC, or 1 to 5 VDC (depending on selection jumper, min 500 O)
Relay: SPST NO 2A @ 30 VDC
CE
Dwyer Instruments CDTV-2N404-LCD | Wall Voc & CO2 transmitter | Universal analog outputs | 2000 ppm CO2 with LCD display Carbon Dioxide/Volatile Organic Compound Transmitter CO2: 0 to 2000 or 0 to 5000 ppm (depending on model)
VOC: 0 to 2000 ppm CO2 equivalent
CO2: ±40 ppm ±3% of reading Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) CO2: 2 minutes for 99% step change; VOC: 5 minutes Average: 2 watts
Peak: 3.75 watts
- Current: 0 to 20 mA, 4 to 20 mA, 0 to 10 mA, or 2 to 10 mA (depending on selection jumper, max 500 O)
Voltage: 0 to 10 VDC, 2 to 10 VDC, 0 to 5 VDC, or 1 to 5 VDC (depending on selection jumper, min 500 O)
Relay: SPST NO 2A @ 30 VDC
CE
Dwyer Instruments CDTV-2N4A4 | Wall Voc & CO2 transmitter | Universal analog outputs | 2000 ppm CO2 | 10K Ohm Type III temperature sensor Carbon Dioxide/Volatile Organic Compound Transmitter CO2: 0 to 2000 or 0 to 5000 ppm (depending on model)
VOC: 0 to 2000 ppm CO2 equivalent
CO2: ±40 ppm ±3% of reading Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) CO2: 2 minutes for 99% step change; VOC: 5 minutes Average: 2 watts
Peak: 3.75 watts
- Current: 0 to 20 mA, 4 to 20 mA, 0 to 10 mA, or 2 to 10 mA (depending on selection jumper, max 500 O)
Voltage: 0 to 10 VDC, 2 to 10 VDC, 0 to 5 VDC, or 1 to 5 VDC (depending on selection jumper, min 500 O)
Relay: SPST NO 2A @ 30 VDC
CE
Dwyer Instruments CDTV-2N4A4-LCD | Wall Voc & CO2 transmitter | Universal analog outputs | 2000 ppm CO2 | 10K Ohm Type III temperature sensor with LCD display Carbon Dioxide/Volatile Organic Compound Transmitter CO2: 0 to 2000 or 0 to 5000 ppm (depending on model)
VOC: 0 to 2000 ppm CO2 equivalent
CO2: ±40 ppm ±3% of reading Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) CO2: 2 minutes for 99% step change; VOC: 5 minutes Average: 2 watts
Peak: 3.75 watts
- Current: 0 to 20 mA, 4 to 20 mA, 0 to 10 mA, or 2 to 10 mA (depending on selection jumper, max 500 O)
Voltage: 0 to 10 VDC, 2 to 10 VDC, 0 to 5 VDC, or 1 to 5 VDC (depending on selection jumper, min 500 O)
Relay: SPST NO 2A @ 30 VDC
CE
Dwyer Instruments CDTV-2N4B4 | Wall Voc & CO2 transmitter | Universal analog outputs | 2000 ppm CO2 | 10K Ohm Type II temperature sensor Carbon Dioxide/Volatile Organic Compound Transmitter Duct Air Velocity: 0-4000 FPM (20.32 m/s) CO2: ±40 ppm ±3% of reading Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) CO2: 2 minutes for 99% step change; VOC: 5 minutes Average: 2 watts
Peak: 3.75 watts
- Current: 0 to 20 mA, 4 to 20 mA, 0 to 10 mA, or 2 to 10 mA (depending on selection jumper, max 500 O)
Voltage: 0 to 10 VDC, 2 to 10 VDC, 0 to 5 VDC, or 1 to 5 VDC (depending on selection jumper, min 500 O)
Relay: SPST NO 2A @ 30 VDC
CE
Dwyer Instruments CDTV-2N4B4-LCD | Wall Voc & CO2 transmitter | Universal analog outputs | 2000 ppm CO2 | 10K Ohm Type II temperature sensor with LCD display Carbon Dioxide/Volatile Organic Compound Transmitter CO2: 0 to 2000 or 0 to 5000 ppm (depending on model)
VOC: 0 to 2000 ppm CO2 equivalent
CO2: ±40 ppm ±3% of reading Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) CO2: 2 minutes for 99% step change; VOC: 5 minutes Average: 2 watts
Peak: 3.75 watts
- Current: 0 to 20 mA, 4 to 20 mA, 0 to 10 mA, or 2 to 10 mA (depending on selection jumper, max 500 O)
Voltage: 0 to 10 VDC, 2 to 10 VDC, 0 to 5 VDC, or 1 to 5 VDC (depending on selection jumper, min 500 O)
Relay: SPST NO 2A @ 30 VDC
CE
Dwyer Instruments CDTR-2N4A4 | Carbon Dioxide/Temperature/Humidity | Wall Mount | Universal current/voltage output | 10 kO Type III Thermistor Temperature Output | North American Housing Carbon Dioxide, Relative Humidity and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Relative humidity: 0 to 100%
Temperature: 32 to 122°F (0 to 50°C)
±40 PPM + 3% of reading (CO2)
±2% (RH)
Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) 2 minutes for 99% step change Average: 2 watts
Peak: 3.75 watts
Limits: 10 to 95% RH (non-condensing) Current: 4 to 20 mA (max 500 Ω)
Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω)
Relay: SPST NO 2A @ 30 VDC
RTD or thermistor per r-t curves (depending on model)
CE
Dwyer Instruments CDTR-2N4A4-LCD | Carbon Dioxide/Temperature/Humidity | Wall Mount | Universal current/voltage output | 10 kO Type III Thermistor Temperature Output | North American Housing | LCD Display Carbon Dioxide, Relative Humidity and Temperature Transmitters Duct Air Velocity: 0-4000 FPM (20.32 m/s) ±40 PPM + 3% of reading (CO2)
±2% (RH)
Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) 2 minutes for 99% step change Average: 2 watts
Peak: 3.75 watts
Limits: 10 to 95% RH (non-condensing) Current: 4 to 20 mA (max 500 Ω)
Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω)
Relay: SPST NO 2A @ 30 VDC
RTD or thermistor per r-t curves (depending on model)
CE
Dwyer Instruments CDTR-2N4B4 | Carbon Dioxide/Temperature/Humidity | Wall Mount | Universal current/voltage output | 10 kO Type II Thermistor Temperature Output | North American Housing Carbon Dioxide, Relative Humidity and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Relative humidity: 0 to 100%
Temperature: 32 to 122°F (0 to 50°C)
±40 PPM + 3% of reading (CO2)
±2% (RH)
Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) 2 minutes for 99% step change Average: 2 watts
Peak: 3.75 watts
Limits: 10 to 95% RH (non-condensing) Current: 4 to 20 mA (max 500 Ω)
Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω)
Relay: SPST NO 2A @ 30 VDC
RTD or thermistor per r-t curves (depending on model)
CE
Dwyer Instruments CDTR-2N4B4-LCD | Carbon Dioxide/Temperature/Humidity | Wall Mount | Universal current/voltage output | 10 kO Type II Thermistor Temperature Output | North American Housing | LCD Display Carbon Dioxide, Relative Humidity and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Relative humidity: 0 to 100%
Temperature: 32 to 122°F (0 to 50°C)
±40 PPM + 3% of reading (CO2)
±2% (RH)
Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) 2 minutes for 99% step change Average: 2 watts
Peak: 3.75 watts
Limits: 10 to 95% RH (non-condensing) Current: 4 to 20 mA (max 500 Ω)
Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω)
Relay: SPST NO 2A @ 30 VDC
RTD or thermistor per r-t curves (depending on model)
CE
Dwyer Instruments CDTR-2N4D4 | Carbon Dioxide/Temperature/Humidity | Wall Mount | Universal current/voltage output | Pt100 O RTD Temperature Output | North American Housing Carbon Dioxide, Relative Humidity and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Relative humidity: 0 to 100%
Temperature: 32 to 122°F (0 to 50°C)
±40 PPM + 3% of reading (CO2)
±2% (RH)
Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) 2 minutes for 99% step change Average: 2 watts
Peak: 3.75 watts
Limits: 10 to 95% RH (non-condensing) Current: 4 to 20 mA (max 500 Ω)
Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω)
Relay: SPST NO 2A @ 30 VDC
RTD or thermistor per r-t curves (depending on model)
CE
Dwyer Instruments CDTR-2N4D4-LCD | Carbon Dioxide/Temperature/Humidity | Wall Mount | Universal current/voltage output | Pt100 O RTD Temperature Output | North American Housing | LCD Display Carbon Dioxide, Relative Humidity and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Relative humidity: 0 to 100%
Temperature: 32 to 122°F (0 to 50°C)
±40 PPM + 3% of reading (CO2)
±2% (RH)
Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) 2 minutes for 99% step change Average: 2 watts
Peak: 3.75 watts
Limits: 10 to 95% RH (non-condensing) Current: 4 to 20 mA (max 500 Ω)
Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω)
Relay: SPST NO 2A @ 30 VDC
RTD or thermistor per r-t curves (depending on model)
CE
Dwyer Instruments CDTR-2N4E4 | Carbon Dioxide/Temperature/Humidity | Wall Mount | Universal current/voltage output | Pt1000 O RTD Temperature Output | North American Housing Carbon Dioxide, Relative Humidity and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Relative humidity: 0 to 100%
Temperature: 32 to 122°F (0 to 50°C)
±40 PPM + 3% of reading (CO2)
±2% (RH)
Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) 2 minutes for 99% step change Average: 2 watts
Peak: 3.75 watts
Limits: 10 to 95% RH (non-condensing) Current: 4 to 20 mA (max 500 Ω)
Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω)
Relay: SPST NO 2A @ 30 VDC
RTD or thermistor per r-t curves (depending on model)
CE
Dwyer Instruments CDTR-2N4E4-LCD | Carbon Dioxide/Temperature/Humidity | Wall Mount | Universal current/voltage output | Pt1000 O RTD Temperature Output | North American Housing | LCD Display Carbon Dioxide, Relative Humidity and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Relative humidity: 0 to 100%
Temperature: 32 to 122°F (0 to 50°C)
±40 PPM + 3% of reading (CO2)
±2% (RH)
Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) 2 minutes for 99% step change Average: 2 watts
Peak: 3.75 watts
Limits: 10 to 95% RH (non-condensing) Current: 4 to 20 mA (max 500 Ω)
Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω)
Relay: SPST NO 2A @ 30 VDC
RTD or thermistor per r-t curves (depending on model)
CE
Dwyer Instruments CDTR-2N4F4 | Carbon Dioxide/Temperature/Humidity | Wall Mount | Universal current/voltage output | 20 kO Thermistor Temperature Output | North American Housing Carbon Dioxide, Relative Humidity and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Relative humidity: 0 to 100%
Temperature: 32 to 122°F (0 to 50°C)
±40 PPM + 3% of reading (CO2)
±2% (RH)
Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) 2 minutes for 99% step change Average: 2 watts
Peak: 3.75 watts
Limits: 10 to 95% RH (non-condensing) Current: 4 to 20 mA (max 500 Ω)
Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω)
Relay: SPST NO 2A @ 30 VDC
RTD or thermistor per r-t curves (depending on model)
CE
Dwyer Instruments CDTR-2N4F4-LCD | Carbon Dioxide/Temperature/Humidity | Wall Mount | Universal current/voltage output | 20 kO Thermistor Temperature Output | North American Housing | LCD Display Carbon Dioxide, Relative Humidity and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Relative humidity: 0 to 100%
Temperature: 32 to 122°F (0 to 50°C)
±40 PPM + 3% of reading (CO2)
±2% (RH)
Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) 2 minutes for 99% step change Average: 2 watts
Peak: 3.75 watts
Limits: 10 to 95% RH (non-condensing) Current: 4 to 20 mA (max 500 Ω)
Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω)
Relay: SPST NO 2A @ 30 VDC
RTD or thermistor per r-t curves (depending on model)
CE
Dwyer Instruments CDTR-5D404 | Carbon Dioxide/RH/Temperature Transmitter | 5000 ppm CO2 range | Duct mount | 4 to 20 mA/0 to (5 or 10) VDC CO2 output | RH outputs & no temperature output Carbon Dioxide, Relative Humidity and Temperature Transmitters CO2: 0 to 2000 or 0 to 5000 PPM (depending on model)
Relative humidity: 0 to 100%
Temperature: 32 to 122°F (0 to 50°C)
±40 PPM + 3% of reading (CO2)
±2% (RH)
Dwyer Instruments 16 to 35 VDC / 19 to 28 VAC 32 to 122°F (0 to 50°C) 2 minutes for 99% step change Average: 2 watts
Peak: 3.75 watts
Limits: 10 to 95% RH (non-condensing) Current: 4 to 20 mA (max 500 Ω)
Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω)
Relay: SPST NO 2A @ 30 VDC
RTD or thermistor per r-t curves (depending on model)
CE
Dwyer Instruments CDWP-02W-C5 | Industrial CO2 Transmitter | 0-2000 PPM range | Wall mount | With 5-8mm cable gland - CO2: 0 to 2000, 0 to 5000, or 0 to 10000 PPM (depending on model) CO2: ±40 PPM + 3% of reading (2000 PPM); ±50 PPM + 5% of reading (5000 PPM); ±50 PPM + 10% of reading (10000 PPM) - 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 300 s (t63) (2000 and 5000 PPM); 2 min for 90% step change (10000 PPM) Average: 2 w
Peak: 3.75 w
Limits: 10 to 95% RH (non-condensing, 2000 and 5000 PPM); 0 to 85% RH (non-condensing, 10000 PPM) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
CE
Dwyer Instruments CDWP-05W-C5 | Industrial CO2 Transmitter | 0-5000 PPM range | Wall mount | With 5-8mm cable gland - CO2: 0 to 2000, 0 to 5000, or 0 to 10000 PPM (depending on model) CO2: ±40 PPM + 3% of reading (2000 PPM); ±50 PPM + 5% of reading (5000 PPM); ±50 PPM + 10% of reading (10000 PPM) - 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 300 s (t63) (2000 and 5000 PPM); 2 min for 90% step change (10000 PPM) Average: 2 w
Peak: 3.75 w
Limits: 10 to 95% RH (non-condensing, 2000 and 5000 PPM); 0 to 85% RH (non-condensing, 10000 PPM) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
CE
Dwyer Instruments CDWP-10W-C1 | Industrial CO2 Transmitter | 0-10 |000 PPM range | Wall mount | With 1-6 mmcable gland - CO2: 0 to 2000, 0 to 5000, or 0 to 10000 PPM (depending on model) CO2: ±40 PPM + 3% of reading (2000 PPM); ±50 PPM + 5% of reading (5000 PPM); ±50 PPM + 10% of reading (10000 PPM) - 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 300 s (t63) (2000 and 5000 PPM); 2 min for 90% step change (10000 PPM) Average: 2 w
Peak: 3.75 w
Limits: 10 to 95% RH (non-condensing, 2000 and 5000 PPM); 0 to 85% RH (non-condensing, 10000 PPM) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
CE
Dwyer Instruments CDWP-10W-C5 | Industrial CO2 Transmitter | 0-10 |000 PPM range | Wall mount | With 5-8mm cable gland - CO2: 0 to 2000, 0 to 5000, or 0 to 10000 PPM (depending on model) CO2: ±40 PPM + 3% of reading (2000 PPM); ±50 PPM + 5% of reading (5000 PPM); ±50 PPM + 10% of reading (10000 PPM) - 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 300 s (t63) (2000 and 5000 PPM); 2 min for 90% step change (10000 PPM) Average: 2 w
Peak: 3.75 w
Limits: 10 to 95% RH (non-condensing, 2000 and 5000 PPM); 0 to 85% RH (non-condensing, 10000 PPM) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
CE
Dwyer Instruments CDTC-2N000 | Communicating carbon dioxide transmitter with temperature output | 2000 PPM range and North American housing - 0 to 2000 or 5000 PPM CO2 (depending on model); 32 to 122°F (0 to 50°C) temperature ±40 PPM ±3% of reading carbon dioxide
Temperature: ± 1°C @ 25°C
- 10-42 VDC or 10-30 VAC 32 to 122°F (0 to 50°C) <2 minutes, diffusion, carbon dioxide - Limits: 10 to 95% RH (non-condensing) 2-wire RS-485, Modbus® RTU or BACnet MS/TP communication protocol BTL, CE
Dwyer Instruments CDTC-2N000-LCD | Communicating carbon dioxide transmitter with temperature output | 2000 PPM range | North American housing and LCD display - 0 to 2000 or 5000 PPM CO2 (depending on model); 32 to 122°F (0 to 50°C) temperature ±40 PPM ±3% of reading carbon dioxide
Temperature: ± 1°C @ 25°C
- 10-42 VDC or 10-30 VAC 32 to 122°F (0 to 50°C) <2 minutes, diffusion, carbon dioxide - Limits: 10 to 95% RH (non-condensing) 2-wire RS-485, Modbus® RTU or BACnet MS/TP communication protocol BTL, CE
Dwyer Instruments CDTC-5N000 | Communicating carbon dioxide transmitter with temperature output | 5000 PPM range and North American housing - 0 to 2000 or 5000 PPM CO2 (depending on model); 32 to 122°F (0 to 50°C) temperature ±40 PPM ±3% of reading carbon dioxide
Temperature: ± 1°C @ 25°C
- 10-42 VDC or 10-30 VAC 32 to 122°F (0 to 50°C) <2 minutes, diffusion, carbon dioxide - Limits: 10 to 95% RH (non-condensing) 2-wire RS-485, Modbus® RTU or BACnet MS/TP communication protocol BTL, CE
Dwyer Instruments CDTC-5N000-LCD | Communicating carbon dioxide transmitter with temperature output | 5000 PPM range | North American housing and LCD display - 0 to 2000 or 5000 PPM CO2 (depending on model); 32 to 122°F (0 to 50°C) temperature ±40 PPM ±3% of reading carbon dioxide
Temperature: ± 1°C @ 25°C
- 10-42 VDC or 10-30 VAC 32 to 122°F (0 to 50°C) <2 minutes, diffusion, carbon dioxide - Limits: 10 to 95% RH (non-condensing) 2-wire RS-485, Modbus® RTU or BACnet MS/TP communication protocol BTL, CE
Dwyer Instruments CDWP-05W-C1 | Industrial CO2 Transmitter | 0-5000 PPM range | Wall mount | With 1-6mm cable gland - CO2: 0 to 2000, 0 to 5000, or 0 to 10000 PPM (depending on model) CO2: ±40 PPM + 3% of reading (2000 PPM); ±50 PPM + 5% of reading (5000 PPM); ±50 PPM + 10% of reading (10000 PPM) - 16-35 VDC or 19-28 VAC 32 to 122°F (0 to 50°C) 300 s (t63) (2000 and 5000 PPM); 2 min for 90% step change (10000 PPM) Average: 2 w
Peak: 3.75 w
Limits: 10 to 95% RH (non-condensing, 2000 and 5000 PPM); 0 to 85% RH (non-condensing, 10000 PPM) Current: 4-20 mA (max. 500 Ω)
Voltage: 0-5 VDC or 0-10 VDC (min. 500 Ω)
CE
Dwyer Instruments CMT-DN-D | Duct mount carbon monoxide transmitter | 4-20 mA and 2-10 VDC outputs | With display - 0 to 125 PPM CO ±2.5% of reading - 24 VDC/VAC at 100 mA - Less than 60 seconds typical for 90% step change - - Current/Voltage: 4 to 20 mA and 2 to 10 VDC
Optional Relay: (2) SPDT 1 Amp dry contact
-
Dwyer Instruments CMT-DN | Duct mount carbon monoxide transmitter | With 4-20 mA and 2-10 VDC outputs - 0 to 125 PPM CO ±2.5% of reading - 24 VDC/VAC at 100 mA - Less than 60 seconds typical for 90% step change - - Current/Voltage: 4 to 20 mA and 2 to 10 VDC
Optional Relay: (2) SPDT 1 Amp dry contact
-
Dwyer Instruments GSTA-C | Carbon Monoxide Transmitter with universal current/voltage outputs - CO: Switch selectable 200 or 500 PPM
NO2: 10 PPM
CO: ±2% FS
NO2: ±3% FS, at the time of calibration
- Current output: 10-35 VDC
Voltage output: 15-35 VDC or 15-29 VAC
Ambient: -4 to 122°F (-20 to 50°C) <45 seconds to 90% CO, <25 to 90% NO2 - Limits: 15 to 90% RH constant; 0 to 99% RH intermittent Drift: <5% per year in air CE
Dwyer Instruments GSTA-C-D | Carbon Monoxide Duct Mount Transmitter with universal current/voltage outputs - CO: Switch selectable 200 or 500 PPM
NO2: 10 PPM
CO: ±2% FS
NO2: ±3% FS, at the time of calibration
- Current output: 10-35 VDC
Voltage output: 15-35 VDC or 15-29 VAC
Ambient: -4 to 122°F (-20 to 50°C) <45 seconds to 90% CO, <25 to 90% NO2 - Limits: 15 to 90% RH constant; 0 to 99% RH intermittent Drift: <5% per year in air CE
Dwyer Instruments GSTA-C-D-FC | Carbon monoxide duct mount transmitter with universal current/voltage outputs | Includes factory calibration certificate - CO: Switch selectable 200 or 500 PPM
NO2: 10 PPM
CO: ±2% FS
NO2: ±3% FS, at the time of calibration
- Current output: 10-35 VDC
Voltage output: 15-35 VDC or 15-29 VAC
Ambient: -4 to 122°F (-20 to 50°C) <45 seconds to 90% CO, <25 to 90% NO2 - Limits: 15 to 90% RH constant; 0 to 99% RH intermittent Drift: <5% per year in air CE
Dwyer Instruments GSTA-C-FC | Carbon monoxide transmitter with universal current/voltage outputs | Includes factory calibration certificate - CO: Switch selectable 200 or 500 PPM
NO2: 10 PPM
CO: ±2% FS
NO2: ±3% FS, at the time of calibration
- Current output: 10-35 VDC
Voltage output: 15-35 VDC or 15-29 VAC
Ambient: -4 to 122°F (-20 to 50°C) <45 seconds to 90% CO, <25 to 90% NO2 - Limits: 15 to 90% RH constant; 0 to 99% RH intermittent Drift: <5% per year in air CE
Dwyer Instruments GSTA-C-LCD | Carbon Monoxide Transmitter with universal current/voltage outputs | LCD display - CO: Switch selectable 200 or 500 PPM
NO2: 10 PPM
CO: ±2% FS
NO2: ±3% FS, at the time of calibration
- Current output: 10-35 VDC
Voltage output: 15-35 VDC or 15-29 VAC
Ambient: -4 to 122°F (-20 to 50°C) <45 seconds to 90% CO, <25 to 90% NO2 - Limits: 15 to 90% RH constant; 0 to 99% RH intermittent Drift: <5% per year in air CE
Dwyer Instruments GSTA-C-LCD-FC | Carbon monoxide transmitter with universal current/voltage outputs | LCD display | Includes factory calibration certificate - CO: Switch selectable 200 or 500 PPM
NO2: 10 PPM
CO: ±2% FS
NO2: ±3% FS, at the time of calibration
- Current output: 10-35 VDC
Voltage output: 15-35 VDC or 15-29 VAC
Ambient: -4 to 122°F (-20 to 50°C) <45 seconds to 90% CO, <25 to 90% NO2 - Limits: 15 to 90% RH constant; 0 to 99% RH intermittent Drift: <5% per year in air CE
Dwyer Instruments GSTA-N | Nitrogen Dioxide Transmitter with universal current/voltage outputs - CO: Switch selectable 200 or 500 PPM
NO2: 10 PPM
CO: ±2% FS
NO2: ±3% FS, at the time of calibration
- Current output: 10-35 VDC
Voltage output: 15-35 VDC or 15-29 VAC
Ambient: -4 to 122°F (-20 to 50°C) <45 seconds to 90% CO, <25 to 90% NO2 - Limits: 15 to 90% RH constant; 0 to 99% RH intermittent Drift: <5% per year in air CE
Dwyer Instruments GSTA-N-D | Nitrogen Dioxide Duct Mount Transmitter with universal current/voltage outputs - CO: Switch selectable 200 or 500 PPM
NO2: 10 PPM
CO: ±2% FS
NO2: ±3% FS, at the time of calibration
- Current output: 10-35 VDC
Voltage output: 15-35 VDC or 15-29 VAC
Ambient: -4 to 122°F (-20 to 50°C) <45 seconds to 90% CO, <25 to 90% NO2 - Limits: 15 to 90% RH constant; 0 to 99% RH intermittent Drift: <5% per year in air CE
Dwyer Instruments GSTA-N-D-FC | Nitrogen duct mount transmitter with universal current/voltage outputs | Includes factory calibration certificate - CO: Switch selectable 200 or 500 PPM
NO2: 10 PPM
CO: ±2% FS
NO2: ±3% FS, at the time of calibration
- Current output: 10-35 VDC
Voltage output: 15-35 VDC or 15-29 VAC
Ambient: -4 to 122°F (-20 to 50°C) <45 seconds to 90% CO, <25 to 90% NO2 - Limits: 15 to 90% RH constant; 0 to 99% RH intermittent Drift: <5% per year in air CE
Dwyer Instruments GSTA-N-FC | Nitrogen transmitter with universal current/voltage outputs | Includes factory calibration certificate - CO: Switch selectable 200 or 500 PPM
NO2: 10 PPM
CO: ±2% FS
NO2: ±3% FS, at the time of calibration
- Current output: 10-35 VDC
Voltage output: 15-35 VDC or 15-29 VAC
Ambient: -4 to 122°F (-20 to 50°C) <45 seconds to 90% CO, <25 to 90% NO2 - Limits: 15 to 90% RH constant; 0 to 99% RH intermittent Drift: <5% per year in air CE
Dwyer Instruments GSTA-N-LCD | Nitrogen Dioxide Transmitter with universal current/voltage outputs | LCD display - CO: Switch selectable 200 or 500 PPM
NO2: 10 PPM
CO: ±2% FS
NO2: ±3% FS, at the time of calibration
- Current output: 10-35 VDC
Voltage output: 15-35 VDC or 15-29 VAC
Ambient: -4 to 122°F (-20 to 50°C) <45 seconds to 90% CO, <25 to 90% NO2 - Limits: 15 to 90% RH constant; 0 to 99% RH intermittent Drift: <5% per year in air CE
Dwyer Instruments GSTA-N-LCD-FC | Nitrogen transmitter with universal current/voltage outputs | LCD display | Includes factory calibration certificate - CO: Switch selectable 200 or 500 PPM
NO2: 10 PPM
CO: ±2% FS
NO2: ±3% FS, at the time of calibration
- Current output: 10-35 VDC
Voltage output: 15-35 VDC or 15-29 VAC
Ambient: -4 to 122°F (-20 to 50°C) <45 seconds to 90% CO, <25 to 90% NO2 - Limits: 15 to 90% RH constant; 0 to 99% RH intermittent Drift: <5% per year in air CE
Dwyer Instruments CMT200 | Carbon Monoxide Transmitter | 0 to 200 PPM CO | 4 to 20 mA/2 to 10 VDC outputs. - 0 to 200 ppm ±2% FS at the time of calibration - Current Output: 18 to 28 VDC
Voltage Output: 18 to 28 VDC/VAC, reverse polarity protected
-4 to 122°F (-20 to 50°C) <45 s. to 90% of final value - Limits: 15 to 90% RH constant
0 to 99% RH intermittent
Jumper selectable 4 to 20 mA (loop powered) or 2 to 10 V (load must be >50 kΩ) CE
Dwyer Instruments CMT200-FC | Carbon monoxide transmitter | 0-200 PPM CO | 4-20 mA/2-10 VDC outputs | Includes factory calibration certificate - 0 to 200 ppm ±2% FS at the time of calibration - Current Output: 18 to 28 VDC
Voltage Output: 18 to 28 VDC/VAC, reverse polarity protected
-4 to 122°F (-20 to 50°C) <45 s. to 90% of final value - Limits: 15 to 90% RH constant
0 to 99% RH intermittent
Jumper selectable 4 to 20 mA (loop powered) or 2 to 10 V (load must be >50 kΩ) CE
Dwyer Instruments CMT200-R | Carbon Monoxide Transmitter | 0 to 200 PPM CO | 4 to 20 mA/2 to 10 VDC outputs | Rectangular enclosure - 0 to 200 ppm ±2% FS at the time of calibration - Current Output: 18 to 28 VDC
Voltage Output: 18 to 28 VDC/VAC, reverse polarity protected
-4 to 122°F (-20 to 50°C) <45 s. to 90% of final value - Limits: 15 to 90% RH constant
0 to 99% RH intermittent
Jumper selectable 4 to 20 mA (loop powered) or 2 to 10 V (load must be >50 kΩ) CE
Dwyer Instruments CMT200-R-FC | Carbon monoxide transmitter | 0-200 PPM CO | 4-20 mA/2-10 VDC outputs | Rectangular enclosure | Includes factory calibration certificate - 0 to 200 ppm ±2% FS at the time of calibration - Current Output: 18 to 28 VDC
Voltage Output: 18 to 28 VDC/VAC, reverse polarity protected
-4 to 122°F (-20 to 50°C) <45 s. to 90% of final value - Limits: 15 to 90% RH constant
0 to 99% RH intermittent
Jumper selectable 4 to 20 mA (loop powered) or 2 to 10 V (load must be >50 kΩ) CE
Dwyer Instruments GSTC-C | Carbon Monoxide Transmitter with BACnet & Modbus Communication - CO: 0 to 500 PPM
NO2: 10 PPM
CO: 2% FS
NO2: 3% FS, at the time of calibration
- 10-36 VDC or isolated 21.6-33 VAC, 5.7 mA @ 24 VDC -4 to 122°F (-20 to 50°C) <45 s to 90% CO, <25 s to 90% NO2 - Limits: 15 to 90% RH constant; 0 to 99% RH intermittent Drift: <5% per year in air CE
Dwyer Instruments GSTC-C-D | Carbon Monoxide Duct Mount Transmitter with BACnet & Modbus Communication - CO: 0 to 500 PPM
NO2: 10 PPM
CO: 2% FS
NO2: 3% FS, at the time of calibration
- 10-36 VDC or isolated 21.6-33 VAC, 5.7 mA @ 24 VDC -4 to 122°F (-20 to 50°C) <45 s to 90% CO, <25 s to 90% NO2 - Limits: 15 to 90% RH constant; 0 to 99% RH intermittent Drift: <5% per year in air CE
Dwyer Instruments GSTC-C-D-FC | Carbon monoxide duct mount transmitter with BACnet & Modbus® communication | Includes factory calibration certificate - CO: 0 to 500 PPM
NO2: 10 PPM
CO: 2% FS
NO2: 3% FS, at the time of calibration
- 10-36 VDC or isolated 21.6-33 VAC, 5.7 mA @ 24 VDC -4 to 122°F (-20 to 50°C) <45 s to 90% CO, <25 s to 90% NO2 - Limits: 15 to 90% RH constant; 0 to 99% RH intermittent Drift: <5% per year in air CE
Dwyer Instruments GSTC-C-FC | Carbon monoxide transmitter with BACnet & Modbus® communication | Includes factory calibration certificate - CO: 0 to 500 PPM
NO2: 10 PPM
CO: 2% FS
NO2: 3% FS, at the time of calibration
- 10-36 VDC or isolated 21.6-33 VAC, 5.7 mA @ 24 VDC -4 to 122°F (-20 to 50°C) <45 s to 90% CO, <25 s to 90% NO2 - Limits: 15 to 90% RH constant; 0 to 99% RH intermittent Drift: <5% per year in air CE
Dwyer Instruments GSTC-C-LCD | Carbon Monoxide Transmitter with BACnet & Modbus Communication with Integral LCD Display - CO: 0 to 500 PPM
NO2: 10 PPM
CO: 2% FS
NO2: 3% FS, at the time of calibration
- 10-36 VDC or isolated 21.6-33 VAC, 5.7 mA @ 24 VDC -4 to 122°F (-20 to 50°C) <45 s to 90% CO, <25 s to 90% NO2 - Limits: 15 to 90% RH constant; 0 to 99% RH intermittent Drift: <5% per year in air CE
Dwyer Instruments GSTC-C-LCD-FC | Carbon monoxide transmitter with BACnet & Modbus® communication | LCD display | Includes factory calibration certificate - CO: 0 to 500 PPM
NO2: 10 PPM
CO: 2% FS
NO2: 3% FS, at the time of calibration
- 10-36 VDC or isolated 21.6-33 VAC, 5.7 mA @ 24 VDC -4 to 122°F (-20 to 50°C) <45 s to 90% CO, <25 s to 90% NO2 - Limits: 15 to 90% RH constant; 0 to 99% RH intermittent Drift: <5% per year in air CE
Dwyer Instruments GSTC-N | Nitrogen Dioxide Transmitter with BACnet & Modbus Communication - CO: 0 to 500 PPM
NO2: 10 PPM
CO: 2% FS
NO2: 3% FS, at the time of calibration
- 10-36 VDC or isolated 21.6-33 VAC, 5.7 mA @ 24 VDC -4 to 122°F (-20 to 50°C) <45 s to 90% CO, <25 s to 90% NO2 - Limits: 15 to 90% RH constant; 0 to 99% RH intermittent Drift: <5% per year in air CE
Dwyer Instruments GSTC-N-D | Nitrogen Dioxide Duct Mount Transmitter with BACnet & Modbus Communication - CO: 0 to 500 PPM
NO2: 10 PPM
CO: 2% FS
NO2: 3% FS, at the time of calibration
- 10-36 VDC or isolated 21.6-33 VAC, 5.7 mA @ 24 VDC -4 to 122°F (-20 to 50°C) <45 s to 90% CO, <25 s to 90% NO2 - Limits: 15 to 90% RH constant; 0 to 99% RH intermittent Drift: <5% per year in air CE
Dwyer Instruments GSTC-N-D-FC | Nitrogen Dioxide duct mount transmitter with BACnet & Modbus® communication | Includes factory calibration certificate - CO: 0 to 500 PPM
NO2: 10 PPM
CO: 2% FS
NO2: 3% FS, at the time of calibration
- 10-36 VDC or isolated 21.6-33 VAC, 5.7 mA @ 24 VDC -4 to 122°F (-20 to 50°C) <45 s to 90% CO, <25 s to 90% NO2 - Limits: 15 to 90% RH constant; 0 to 99% RH intermittent Drift: <5% per year in air CE
Dwyer Instruments GSTC-N-FC | Nitrogen Dioxide transmitter with BACnet & Modbus® communication | Includes factory calibration certificate - CO: 0 to 500 PPM
NO2: 10 PPM
Drift: <5% per year in air - 10-36 VDC or isolated 21.6-33 VAC, 5.7 mA @ 24 VDC -4 to 122°F (-20 to 50°C) <45 s to 90% CO, <25 s to 90% NO2 - Limits: 15 to 90% RH constant; 0 to 99% RH intermittent CO: 2% FS
NO2: 3% FS, at the time of calibration
CE
Dwyer Instruments GSTC-N-LCD | Nitrogen Dioxide Transmitter with BACnet & Modbus Communication with Integral LCD Display - CO: 0 to 500 PPM
NO2: 10 PPM
CO: 2% FS
NO2: 3% FS, at the time of calibration
- 10-36 VDC or isolated 21.6-33 VAC, 5.7 mA @ 24 VDC -4 to 122°F (-20 to 50°C) <45 s to 90% CO, <25 s to 90% NO2 - Limits: 15 to 90% RH constant; 0 to 99% RH intermittent Drift: <5% per year in air CE
Dwyer Instruments GSTC-N-LCD-FC | Nitrogen Dioxide duct mount transmitter with BACnet & Modbus® communication | LCD display | Includes factory calibration certificate - CO: 0 to 500 PPM
NO2: 10 PPM
CO: 2% FS
NO2: 3% FS, at the time of calibration
- 10-36 VDC or isolated 21.6-33 VAC, 5.7 mA @ 24 VDC -4 to 122°F (-20 to 50°C) <45 s to 90% CO, <25 s to 90% NO2 - Limits: 15 to 90% RH constant; 0 to 99% RH intermittent Drift: <5% per year in air CE
Dwyer Instruments CMS300 | Carbon monoxide transmitter & switch | 0-300 PPM | 4-20 mA/2-10 V (maximum load 2K Ω) Switch: Single-pole double-throw (SPDT) 0-300 PPM ±5 PPM or 5% of reading for 0-300 PPM (whichever is greater) - - - <45 seconds to 90% of final value - Range: 15-90% RH constant; 0-99% RH intermittent Drift: <5% per year in air Sensor is UL recognized component for ANSI/UL-2034, UL-2075, E340403, CE
Dwyer Instruments CMS300-FC | Carbon monoxide transmitter & switch | 0-300 PPM | 4-20 mA/2-10 V (maximum load 2K Ω) | Includes factory calibration certificate Switch: Single-pole double-throw (SPDT) 0-300 PPM ±5 PPM or 5% of reading for 0-300 PPM (whichever is greater) - - - <45 seconds to 90% of final value - Range: 15-90% RH constant; 0-99% RH intermittent Analog: Jumper selectable 4 to 20 mA (loop powered) or 2 to 10 V (maximum load 2 kΩ) Sensor is UL recognized component for ANSI/UL-2034, UL-2075, E340403, CE