Whatsapp

Model Options

Edit these specs to order a different model. Not all combinations are valid. Options compatible with previous selections will be in bold.

CE
Capacitance polymer
±1%
Duct Mount only, optional 2-line alpha numeric, 8 characters/line
Duct Mount only, optional 2-line alpha numeric, 8 characters/lineRH: 0.1%; 0.1°F (0.1°C)
±1%
Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg)
RH: 0.1%; 0.1°F (0.1°C)
Humidity and Temperature Transmitter
RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C
RTD Temp Sensor: DIN Class B; ±0.3°C @ 0°C (±0.54°F @ 32°F)
Solid State Band Gap: ±0.9°F @ 77°F (±0.5°C @ 25°C)
Thermistor Temp Sensor: ±0.2°C @ 25°C (±0.36°F @ 77°F)
Range: 0 to 100% RH
>Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Dwyer Instruments
Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66)
Duct Mount only, optional 2-line alpha numeric, 8 characters/line
RH: 0.1%; 0.1°F (0.1°C)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate.
<1% RH/year
Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm)
Electrical: Removable screw terminal block
15 s
4-20 mA; 0-5/10V @ 5 mA max
4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC
-40 to 140°F (-40 to 60°C)
Compensated: -4 to 140°F (-20 to 60°C)
-40 to 176°F (-40 to 80°C)
Limit: -40 to 140°F (-40 to 60°C)
±0.1% typical
product

Dwyer Instruments RHP-2D1B | Duct mount 2% RH/temperature transmitter with 4-20 mA RH output and 10K @ 25°C thermistor temperature output

Brand : Image Brand
Stock Status : Contact us for delivery
Brand : Image Brand
Stock Status : Out of Stock

Part Number : RHP-2D1B

A passive temperature thermistor or RTD output is combined with the voltage or current humidity transmitter output in the Series RHP, Model RHP-2D1B humidity and temperature transmitter. Models with polymer capacitance humidity sensors come in 2%, 3%, or 5% accuracy options. A two-line alpha numeric LCD display is an optional feature for duct mounted transmitters.

Quantity:
Provide Calibration Services  
  • Specification
  • Features
  • Catalog
Product Name Type Accuracy Repeatability Display Weight Manufacturer Temperature Power Display Resolution Response Time Storage Temperature Temperature Range Connection TEMPERATURE SENSOR ENCLOSURE MATERIAL Relative Humidity Output Signal Approvals Sensor Type Enclosure Rating Drift Hysteresis
Dwyer Instruments RHPX-2SDA0-00-LCD | Relative Humidity/Temperature transmitter | 2% small enclosure | Duct | Analog output | LCD Relative Humidity/Temperature transmitter Temperature Sensor Accuracy, RTD: DIN Class B; ±0.3°C @ 0°C (±0.54°F @ 32°F) (analog models only) - Optional: Two (2) lines of alphanumeric characters with eight (8) characters per line Duct: 198.4 g (0.44 lb); wall mount: 170 g (0.38 lb); large housing: 340.2 g (0.75 lb); large housing with radiation shield: 1247.4 g (2.75 lb) - 4-20 mA or 0-5 V dc, 0-10 V dc at 5 mA max, field selectable Communications model: 14 to 35 Vdc or 10 to 32 Vac; Analog model: 4-20 mA: 10 to 35 Vdc; Vout: 15 to 35 Vdc or 15 to 29 Vac - - -40°C to 70°C (-40°F to 158°F); With LCD: -30°C to 70°C (-22°F to 158°F) - Wiring: Removable terminal block - UL 94 V-0 - - BTL, CE, UL 2043*, UL-60335-2-40** Types II and III: Solid state band gap
Curves A, B, and F: Thermistor
Curves D and E: Platinum RTD DIN 385, Balco 1K (analog models only, availability is sensor configuration dependent)
IP66 - -
Dwyer Instruments RHPX-3SDA0-00 | Relative Humidity/Temperature transmitter | 3% small enclosure | Duct | Analog output Relative Humidity/Temperature transmitter Temperature Sensor Accuracy, RTD: DIN Class B; ±0.3°C @ 0°C (±0.54°F @ 32°F) (analog models only) - Optional: Two (2) lines of alphanumeric characters with eight (8) characters per line Duct: 198.4 g (0.44 lb); wall mount: 170 g (0.38 lb); large housing: 340.2 g (0.75 lb); large housing with radiation shield: 1247.4 g (2.75 lb) - 4-20 mA or 0-5 V dc, 0-10 V dc at 5 mA max, field selectable Communications model: 14 to 35 Vdc or 10 to 32 Vac; Analog model: 4-20 mA: 10 to 35 Vdc; Vout: 15 to 35 Vdc or 15 to 29 Vac - - -40°C to 70°C (-40°F to 158°F); With LCD: -30°C to 70°C (-22°F to 158°F) - Wiring: Removable terminal block - UL 94 V-0 - - BTL, CE, UL 2043*, UL-60335-2-40** Types II and III: Solid state band gap
Curves A, B, and F: Thermistor
Curves D and E: Platinum RTD DIN 385, Balco 1K (analog models only, availability is sensor configuration dependent)
IP66 - -
Dwyer Instruments RHPX-2SDA0-00 | Relative Humidity/Temperature transmitter | 2% small enclosure | Duct | Analog output Relative Humidity/Temperature transmitter Temperature Sensor Accuracy, RTD: DIN Class B; ±0.3°C @ 0°C (±0.54°F @ 32°F) (analog models only) - Optional: Two (2) lines of alphanumeric characters with eight (8) characters per line Duct: 198.4 g (0.44 lb); wall mount: 170 g (0.38 lb); large housing: 340.2 g (0.75 lb); large housing with radiation shield: 1247.4 g (2.75 lb) - 4-20 mA or 0-5 V dc, 0-10 V dc at 5 mA max, field selectable Communications model: 14 to 35 Vdc or 10 to 32 Vac; Analog model: 4-20 mA: 10 to 35 Vdc; Vout: 15 to 35 Vdc or 15 to 29 Vac - - -40°C to 70°C (-40°F to 158°F); With LCD: -30°C to 70°C (-22°F to 158°F) - Wiring: Removable terminal block - UL 94 V-0 - - BTL, CE, UL 2043*, UL-60335-2-40** Types II and III: Solid state band gap
Curves A, B, and F: Thermistor
Curves D and E: Platinum RTD DIN 385, Balco 1K (analog models only, availability is sensor configuration dependent)
IP66 - -
Dwyer Instruments RHPX-3SDA0-00-LCD | Relative Humidity/Temperature transmitter | 3% small enclosure | Duct | Analog output | LCD Relative Humidity/Temperature transmitter Temperature Sensor Accuracy, RTD: DIN Class B; ±0.3°C @ 0°C (±0.54°F @ 32°F) (analog models only) - Optional: Two (2) lines of alphanumeric characters with eight (8) characters per line Duct: 198.4 g (0.44 lb); wall mount: 170 g (0.38 lb); large housing: 340.2 g (0.75 lb); large housing with radiation shield: 1247.4 g (2.75 lb) - 4-20 mA or 0-5 V dc, 0-10 V dc at 5 mA max, field selectable Communications model: 14 to 35 Vdc or 10 to 32 Vac; Analog model: 4-20 mA: 10 to 35 Vdc; Vout: 15 to 35 Vdc or 15 to 29 Vac - - -40°C to 70°C (-40°F to 158°F); With LCD: -30°C to 70°C (-22°F to 158°F) - Wiring: Removable terminal block - UL 94 V-0 - - BTL, CE, UL 2043*, UL-60335-2-40** Types II and III: Solid state band gap
Curves A, B, and F: Thermistor
Curves D and E: Platinum RTD DIN 385, Balco 1K (analog models only, availability is sensor configuration dependent)
IP66 - -
Dwyer Instruments RHP-2D2A | Duct mount 2% RH/temperature transmitter with 0-10 VDC RH output and 10K Curve A passive temperature output Humidity and Temperature Transmitter Solid State Band Gap: ±0.9°F @ 77°F (±0.5°C @ 25°C) ±0.1% typical - Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) Compensated: -4 to 140°F (-20 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2D2B | Duct mount 2% RH/temperature transmitter with 0-10 VDC RH output and 10K @ 25°C thermistor temperature output Humidity and Temperature Transmitter RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2D2D | Duct mount 2% RH/temperature transmitter with 0-10 VDC RH output and 100 Ohm RTD Curve D passive temperature output Humidity and Temperature Transmitter Solid State Band Gap: ±0.9°F @ 77°F (±0.5°C @ 25°C) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) Compensated: -4 to 140°F (-20 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2D2E | Duct mount 2% RH/temperature transmitter with 0-10 VDC RH output and 1K Ohm RTD DIN 385 temperature output Humidity and Temperature Transmitter RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2D2F | Duct mount 2% RH/temperature transmitter with 0-10 VDC RH output and 20K NTC thermistor temperature output Humidity and Temperature Transmitter Thermistor Temp Sensor: ±0.2°C @ 25°C (±0.36°F @ 77°F) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) Compensated: -4 to 140°F (-20 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2D20 | Duct mount 2% RH transmitter with 0-10 VDC RH output Humidity and Temperature Transmitter RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2D1A | Duct mount 2% RH/temperature transmitter with 4-20 mA RH output and 10K Curve A passive temperature output Humidity and Temperature Transmitter Thermistor Temp Sensor: ±0.2°C @ 25°C (±0.36°F @ 77°F) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE ±1% Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2D1D | Duct mount 2% RH/temperature transmitter with 4-20 mA RH output and 100 Ohm RTD Curve D passive temperature output Humidity and Temperature Transmitter Solid State Band Gap: ±0.9°F @ 77°F (±0.5°C @ 25°C) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC - 15 s -40 to 176°F (-40 to 80°C) Compensated: -4 to 140°F (-20 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2D1E | Duct mount 2% RH/temperature transmitter with 4-20 mA RH output and 1K Ohm RTD DIN 385 temperature output Humidity and Temperature Transmitter Solid State Band Gap: ±0.9°F @ 77°F (±0.5°C @ 25°C) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) Compensated: -4 to 140°F (-20 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments 657-1 | Relative humidity/temperature transmitter Relative Humidity/Temperature Transmitters Relative humidity: ±2% (10 to 90% RH), ±3% (0 to 10% and 90 to 100% RH); Temperature ±1°F (0.5°C) - - 5.5 oz (156 g) Dwyer Instruments - 10-35 VDC - - - Compensated: 32 to 140°F (0 to 60°C) Electrical: 4 screw type terminals - - - 2 channels each 4-20 mA. Loop powered on the RH channel - - - - -
Dwyer Instruments 657C-1 | Relative humidity/temperature transmitter Relative Humidity/Temperature Transmitters Relative humidity: ±2% (10 to 90% RH), ±3% (0 to 10% and 90 to 100% RH); Temperature ±1°F (0.5°C) - - 10 oz (284 g) Dwyer Instruments - 10-35 VDC - - - Compensated: 32 to 140°F (0 to 60°C) Electrical: 4 screw type terminals - - - 2 channels each 4-20 mA. Loop powered on the RH channel - - - - -
Dwyer Instruments RHT-R008 | Humidity/Temperature Transmitter | 8' cable | Current output Humidity Transmitter ±2% @ 10 to 90% - - - Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 10 to 35 VDC - Less than 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Electrical: Terminal block - - Range: 0 to 100% RH 4 to 20 mA loop powered - Capacitance polymer NEMA 4X (IP66) Less than 1%/year -
Dwyer Instruments RHT-R016 | Humidity/Temperature Transmitter | 16' cable | Current output Humidity Transmitter ±2% @ 10 to 90% - - - Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 10 to 35 VDC - Less than 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Electrical: Terminal block - - Range: 0 to 100% RH 4 to 20 mA loop powered - Capacitance polymer NEMA 4X (IP66) Less than 1%/year -
Dwyer Instruments RHU-R008 | Humidity Transmitter | 8' cable | Current output Humidity Transmitter ±2% @ 10 to 90% - - - Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 10 to 35 VDC - Less than 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: 1/2" NPT - - Range: 0 to 100% RH 4 to 20 mA loop powered - Capacitance polymer NEMA 4X (IP66) Less than 1%/year -
Dwyer Instruments RHU-R016 | Humidity Transmitter | 16' cable | Current output Humidity Transmitter ±2% @ 10 to 90% - - - Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 10 to 35 VDC - Less than 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: 1/2" NPT - - Range: 0 to 100% RH 4 to 20 mA loop powered - Capacitance polymer NEMA 4X (IP66) Less than 1%/year -
Dwyer Instruments RHP-3M10 | Sintered filter duct mount humidity transmitter with 3% sensor | 4 to 20 mA humidity output Humidity and Temperature Transmitter RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) Compensated: -4 to 140°F (-20 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3M11 | Sintered filter duct mount humidity/temperature transmitter with 3% sensor | 4 to 20mA humidity/temperature output Humidity and Temperature Transmitter RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3M1A | Sintered filter duct mount humidity/temperature transmitter with 3% sensor | 4 to 20 mA humidity output | 10K Type III NTC thermistor temperature output Humidity and Temperature Transmitter Solid State Band Gap: ±0.9°F @ 77°F (±0.5°C @ 25°C) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) Compensated: -4 to 140°F (-20 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3M1B | Sintered filter duct mount humidity/temperature transmitter with 3% sensor | 4 to 20 mA humidity output | 10K type II NTC thermistor temperature output Humidity and Temperature Transmitter RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3M20 | Sintered filter duct mount humidity transmitter with 3% sensor | 0 to 10 VDC humidity output Humidity and Temperature Transmitter Solid State Band Gap: ±0.9°F @ 77°F (±0.5°C @ 25°C) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) Compensated: -4 to 140°F (-20 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2D1F | Duct mount 2% RH/temperature transmitter with 4-20 mA RH output and 20K NTC thermistor temperature output Humidity and Temperature Transmitter Solid State Band Gap: ±0.9°F @ 77°F (±0.5°C @ 25°C) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) Compensated: -4 to 140°F (-20 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2D10 | Duct mount 2% RH transmitter with 4-20 mA RH output Humidity and Temperature Transmitter Solid State Band Gap: ±0.9°F @ 77°F (±0.5°C @ 25°C) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2M11 | Sintered filter duct mount humidity/temperature transmitter with 2% sensor | 4 to 20 mA output for humidity and temperature Humidity and Temperature Transmitter Solid State Band Gap: ±0.9°F @ 77°F (±0.5°C @ 25°C) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) Compensated: -4 to 140°F (-20 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2O10 | OSA 2% RH transmitter with 4-20 mA RH output Humidity and Temperature Transmitter Solid State Band Gap: ±0.9°F @ 77°F (±0.5°C @ 25°C) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2O11 | OSA 2% RH/temperature transmitter with 4-20 mA RH output and 4-20 mA temperature output Humidity and Temperature Transmitter RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3D1A | Duct mount 3% RH/temperature transmitter with 4-20 mA RH output and 10K @ 25°C thermistor temperature output Humidity and Temperature Transmitter RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3D1B | Duct mount 3% RH/temperature transmitter with 4-20 mA RH output and 10K @ 25°C thermistor temperature output Humidity and Temperature Transmitter Solid State Band Gap: ±0.9°F @ 77°F (±0.5°C @ 25°C) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) Compensated: -4 to 140°F (-20 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3D1D | Duct mount 3% RH/temperature transmitter with 4-20 mA RH output and 100 Ohm RTD DIN 385 temperature output Humidity and Temperature Transmitter RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3D1F | Duct mount 3% RH/temperature transmitter with 4-20 mA RH output and 20K NTC thermistor temperature output Humidity and Temperature Transmitter RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3D2B | Duct mount 3% RH/temperature transmitter with 0-10 VDC RH output and 10K @ 25°C thermistor temperature output Humidity and Temperature Transmitter Solid State Band Gap: ±0.9°F @ 77°F (±0.5°C @ 25°C) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) Compensated: -4 to 140°F (-20 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3D2E | Duct mount 3% RH/temperature transmitter with 0-10 VDC RH output and 1K Ohm RTD DIN 385 temperature output Humidity and Temperature Transmitter Thermistor Temp Sensor: ±0.2°C @ 25°C (±0.36°F @ 77°F) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3D2F | Duct mount 3% RH/temperature transmitter with 0-10 VDC RH output and 20K NTC thermistor temperature output Humidity and Temperature Transmitter Solid State Band Gap: ±0.9°F @ 77°F (±0.5°C @ 25°C) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3D20 | Duct mount 3% RH transmitter with 0-10 VDC RH output Humidity and Temperature Transmitter Solid State Band Gap: ±0.9°F @ 77°F (±0.5°C @ 25°C) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) Compensated: -4 to 140°F (-20 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3D3E | Duct humidity/temperature transmitter with 3% sensor | 0 to 5 V humidity output | Pt1000 RTD temperature output Humidity and Temperature Transmitter RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3D2D | Duct mount 3% RH/temperature transmitter with 0-10 VDC RH output and 100 Ohm RTD DIN 385 temperature output Humidity and Temperature Transmitter RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s Compensated: -4 to 140°F (-20 to 60°C) -40 to 140°F (-40 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2O1A | OSA mount 2% RH/temperature transmitter with 4-20 mA RH output and 10K type III NTC thermistor temperature output Humidity and Temperature Transmitter Thermistor Temp Sensor: ±0.2°C @ 25°C (±0.36°F @ 77°F) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2O1B | OSA mount 2% RH/temperature transmitter with 4-20 mA RH output and 10K type II NTC thermistor temperature output Humidity and Temperature Transmitter Solid State Band Gap: ±0.9°F @ 77°F (±0.5°C @ 25°C) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) Compensated: -4 to 140°F (-20 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2O1D | OSA mount 2% RH/temperature transmitter with 4-20 mA RH output and Pt100 RTD temperature output Humidity and Temperature Transmitter Thermistor Temp Sensor: ±0.2°C @ 25°C (±0.36°F @ 77°F) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2O1E | OSA mount 2% RH/temperature transmitter with 4-20 mA RH output and Pt1000 RTD temperature output Humidity and Temperature Transmitter Thermistor Temp Sensor: ±0.2°C @ 25°C (±0.36°F @ 77°F) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2O1F | OSA mount 2% RH/temperature transmitter with 4-20 mA RH output and 20K NTC thermistor temperature output Humidity and Temperature Transmitter Thermistor Temp Sensor: ±0.2°C @ 25°C (±0.36°F @ 77°F) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2O20 | OSA 2% RH transmitter with 0-10 VDC RH output Humidity and Temperature Transmitter Solid State Band Gap: ±0.9°F @ 77°F (±0.5°C @ 25°C) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/lineRH: 0.1%; 0.1°F (0.1°C) Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2O2A | OSA mount 2% RH/temperature transmitter with 0-10 VDC RH output and 10K type III NTC thermistor temperature output Humidity and Temperature Transmitter RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) Compensated: -4 to 140°F (-20 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2O2B | OSA mount 2% RH/temperature transmitter with 0-10 VDC RH output and 10K type II NTC thermistor temperature output Humidity and Temperature Transmitter RTD Temp Sensor: DIN Class B; ±0.3°C @ 0°C (±0.54°F @ 32°F) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2O2D | OSA mount 2% RH/temperature transmitter with 0-10 VDC RH output and Pt100 RTD temperature output Humidity and Temperature Transmitter Solid State Band Gap: ±0.9°F @ 77°F (±0.5°C @ 25°C) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) Compensated: -4 to 140°F (-20 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2O2E | OSA mount 2% RH/temperature transmitter with 0-10 VDC RH output and Pt1000 RTD temperature output Humidity and Temperature Transmitter RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2O2F | OSA mount 2% RH/temperature transmitter with 0-10 VDC RH output and 20K NTC thermistor temperature output Humidity and Temperature Transmitter RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3D1E | Duct mount 3% RH/temperature transmitter with 4-20 mA RH output and 1K Ohm RTD DIN 385 temperature output Humidity and Temperature Transmitter Solid State Band Gap: ±0.9°F @ 77°F (±0.5°C @ 25°C) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) Compensated: -4 to 140°F (-20 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3O10 | OSA 3% RH transmitter with 4-20 mA RH output Humidity and Temperature Transmitter RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) Compensated: -4 to 140°F (-20 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3O11 | OSA 3% RH/temperature transmitter with 4-20 mA RH output and 4-20 mA temperature output Humidity and Temperature Transmitter Thermistor Temp Sensor: ±0.2°C @ 25°C (±0.36°F @ 77°F) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3O1A | OSA mount 3% RH/temperature transmitter with 4-20 mA RH output and 10K type III NTC thermistor temperature output Humidity and Temperature Transmitter Thermistor Temp Sensor: ±0.2°C @ 25°C (±0.36°F @ 77°F) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3O1B | OSA mount 3% RH/temperature transmitter with 4-20 mA RH output and 10K type II NTC thermistor temperature output Humidity and Temperature Transmitter Solid State Band Gap: ±0.9°F @ 77°F (±0.5°C @ 25°C) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3O1D | OSA mount 3% RH/temperature transmitter with 4-20 mA RH output and Pt100 RTD temperature output Humidity and Temperature Transmitter Thermistor Temp Sensor: ±0.2°C @ 25°C (±0.36°F @ 77°F) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3O1E | OSA mount 3% RH/temperature transmitter with 4-20 mA RH output and Pt1000 RTD temperature output Humidity and Temperature Transmitter Thermistor Temp Sensor: ±0.2°C @ 25°C (±0.36°F @ 77°F) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3O1F | OSA mount 3% RH/temperature transmitter with 4-20 mA RH output and 20K NTC thermistor temperature output Humidity and Temperature Transmitter RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3O20 | OSA 3% RH transmitter with 0-10 VDC RH output Humidity and Temperature Transmitter Solid State Band Gap: ±0.9°F @ 77°F (±0.5°C @ 25°C) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) Compensated: -4 to 140°F (-20 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3O22 | OSA mount 3% RH/temperature transmitter with 0-10 VDC RH output and 0-10 VDC temperature output Humidity and Temperature Transmitter RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2R11 | OSA humidity/temperature transmitter with 2% sensor | 4 to 20 mA humidity/temperature output with radiation shield. Humidity and Temperature Transmitter Thermistor Temp Sensor: ±0.2°C @ 25°C (±0.36°F @ 77°F) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3O2A | OSA mount 3% RH/temperature transmitter with 0-10 VDC RH output and 10K type III NTC thermistor temperature output Humidity and Temperature Transmitter Solid State Band Gap: ±0.9°F @ 77°F (±0.5°C @ 25°C) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) Compensated: -4 to 140°F (-20 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3O2B | OSA mount 3% RH/temperature transmitter with 0-10 VDC RH output and 10K type II NTC thermistor temperature output Humidity and Temperature Transmitter Thermistor Temp Sensor: ±0.2°C @ 25°C (±0.36°F @ 77°F) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2R1B | OSA humidity/temperature transmitter with 2% sensor | 4 to 20 mA humidity output | 10K type II thermistor temperature output with radiation shield Humidity and Temperature Transmitter Thermistor Temp Sensor: ±0.2°C @ 25°C (±0.36°F @ 77°F) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3O2E | OSA mount 3% RH/temperature transmitter with 0-10 VDC RH output and Pt1000 RTD temperature output Humidity and Temperature Transmitter RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) Compensated: -4 to 140°F (-20 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3O2F | OSA mount 3% RH/temperature transmitter with 0-10 VDC RH output and 20K NTC thermistor temperature output Humidity and Temperature Transmitter RTD Temp Sensor: DIN Class B; ±0.3°C @ 0°C (±0.54°F @ 32°F) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) Compensated: -4 to 140°F (-20 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3D10 | Duct mount 3% RH transmitter with 4-20 mA RH output Humidity and Temperature Transmitter RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3R11 | OSA humidity/temperature transmitter with 3% sensor | 4 to 20 mA humidity/temperature output with radiation shield Humidity and Temperature Transmitter RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2S1B | Sintered filter OSA humidity/temperature transmitter with 2% sensor | 4 to 20 mA humidity output | 10K type II NTC thermistor temperature output Humidity and Temperature Transmitter Thermistor Temp Sensor: ±0.2°C @ 25°C (±0.36°F @ 77°F) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3S1A | Sintered filter OSA humidity/temperature transmitter with 3% sensor | 4 to 20 mA humidity output | 10K type III NTC thermistor temperature output Humidity and Temperature Transmitter Thermistor Temp Sensor: ±0.2°C @ 25°C (±0.36°F @ 77°F) Limit: -40 to 140°F (-40 to 60°C) Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments -40 to 176°F (-40 to 80°C) 4-20 mA; 0-5/10V @ 5 mA max RH: 0.1%; 0.1°F (0.1°C) - Compensated: -4 to 140°F (-20 to 60°C) -40 to 140°F (-40 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 15 s CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3S1B | Sintered filter OSA humidity/temperature transmitter with 3% sensor | 4 to 20 mA humidity output | 10K type II NTC thermistor temperature output Humidity and Temperature Transmitter RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line RH: 0.1%; 0.1°F (0.1°C) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC Duct Mount only, optional 2-line alpha numeric, 8 characters/line 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-2S11 | Sintered filter OSA humidity/temperature transmitter with 2% sensor | 4 to 20 mA humidity/temperature output Humidity and Temperature Transmitter RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3S11 | Sintered filter OSA humidity/temperature transmitter with 3% sensor | 4 to 20 mA humidity/temperature output Humidity and Temperature Transmitter Thermistor Temp Sensor: ±0.2°C @ 25°C (±0.36°F @ 77°F) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3S22 | Sintered filter OSA humidity/temperature transmitter with 3% sensor | 0 to 10 VDC humidity/temperature output Humidity and Temperature Transmitter RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Electrical: Removable screw terminal block >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3S2A | Sintered filter OSA humidity/temperature transmitter with 3% sensor | 0 to 10 VDC humidity output | 10K type III NTC thermistor temperature output Humidity and Temperature Transmitter RTD Temp Sensor: DIN Class B; ±0.3°C @ 0°C (±0.54°F @ 32°F) ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments RHP-3S2B | Sintered filter OSA humidity/temperature transmitter with 3% sensor | 0 to 10 VDC humidity output | 10K type II NTC thermistor temperature output Humidity and Temperature Transmitter RH: RHP-2XXX ±2% 10 to 90% RH @ 25°C;RHP-3XXX ±3% 20 to 80% RH @ 25°C;RHP-5XXX ±5% 20 to 80% RH @ 25°C ±0.1% typical Duct Mount only, optional 2-line alpha numeric, 8 characters/line Duct Mount: .616 lb (.3 kg) OSA: 1 lb (.45 kg) Dwyer Instruments Limit: -40 to 140°F (-40 to 60°C) 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC RH: 0.1%; 0.1°F (0.1°C) 15 s -40 to 176°F (-40 to 80°C) Compensated: -4 to 140°F (-20 to 60°C) Conduit: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm) >Types 1, 2, 3: Solid state band gap
Curves A,B,C; Thermistor
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table)
Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate. Range: 0 to 100% RH 4-20 mA; 0-5/10V @ 5 mA max CE Capacitance polymer Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66) <1% RH/year ±1%
Dwyer Instruments WHT-310 | Water-resistant humidity transmitter with sintered filter | 3% accuracy | 4-20 mA humidity output - 4 to 20 mA Output: ±0.9°F @ 72°F (±0.3°C @ 25°C)
Passive Output: ±0.36°F @ 77°F (±0.2°C @ 25°C)
RH: ±0.1% typical - 0.3 oz (8.5 g) - - 4-20 mA loop powered models: 10-35 VDC; 0-10 V output models: 15-35 VDC or 15-29 VAC; 0-5 V output models: 10-35 VDC or 10-29 VAC - 15 s -40 to 176°F (-40 to 80°C) Compensated, RH: -4 to 140°F (-20 to 60°C) Electrical: Removable screw terminal block 4 to 20 mA output: solid state band gap; Passive output: 10K @ 25°C thermistor (Dwyer curve A) - Range: 0 to 100% RH 4-20 mA loop powered models: 4-20 mA; 0-10 V output models: 0-10 V @ 5 mA max; 0-5 V output models: 0-5 V @ 5 mA max CE Capacitance polymer Designed to meet NEMA 3S (IP54) <1% RH/year RH: ±1%
Dwyer Instruments WHT-311 | Water-resistant humidity/temperature transmitter with sintered filter | 3% accuracy | 4-20 mA humidity and temperature output - 4 to 20 mA Output: ±0.9°F @ 72°F (±0.3°C @ 25°C)
Passive Output: ±0.36°F @ 77°F (±0.2°C @ 25°C)
RH: ±0.1% typical - 0.3 oz (8.5 g) - - 4-20 mA loop powered models: 10-35 VDC; 0-10 V output models: 15-35 VDC or 15-29 VAC; 0-5 V output models: 10-35 VDC or 10-29 VAC - 15 s -40 to 176°F (-40 to 80°C) Compensated, RH: -4 to 140°F (-20 to 60°C) Electrical: Removable screw terminal block 4 to 20 mA output: solid state band gap; Passive output: 10K @ 25°C thermistor (Dwyer curve A) - Range: 0 to 100% RH 4-20 mA loop powered models: 4-20 mA; 0-10 V output models: 0-10 V @ 5 mA max; 0-5 V output models: 0-5 V @ 5 mA max CE Capacitance polymer Designed to meet NEMA 3S (IP54) <1% RH/year RH: ±1%
Dwyer Instruments WHT-31A | Water-resistant humidity/temperature transmitter with sintered filter | 3% accuracy | 4-20 mA humidity output and 10K ? Type III | curve A temperature output - 4 to 20 mA Output: ±0.9°F @ 72°F (±0.3°C @ 25°C)
Passive Output: ±0.36°F @ 77°F (±0.2°C @ 25°C)
RH: ±0.1% typical - 0.3 oz (8.5 g) - - 4-20 mA loop powered models: 10-35 VDC; 0-10 V output models: 15-35 VDC or 15-29 VAC; 0-5 V output models: 10-35 VDC or 10-29 VAC - 15 s -40 to 176°F (-40 to 80°C) Compensated, RH: -4 to 140°F (-20 to 60°C) Electrical: Removable screw terminal block 4 to 20 mA output: solid state band gap; Passive output: 10K @ 25°C thermistor (Dwyer curve A) - Range: 0 to 100% RH 4-20 mA loop powered models: 4-20 mA; 0-10 V output models: 0-10 V @ 5 mA max; 0-5 V output models: 0-5 V @ 5 mA max CE Capacitance polymer Designed to meet NEMA 3S (IP54) <1% RH/year RH: ±1%
Dwyer Instruments WHT-320 | Water-resistant humidity transmitter with sintered filter | 3% accuracy | 0-10 VDC humidity output - Sensor, RH: ±2% 20 to 80% RH, ±3% @ 10 to 20%, 80 to 90% RH RH: ±0.1% typical - 0.3 oz (8.5 g) - - 4-20 mA loop powered models: 10-35 VDC; 0-10 V output models: 15-35 VDC or 15-29 VAC; 0-5 V output models: 10-35 VDC or 10-29 VAC - 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Electrical: Removable screw terminal block 4 to 20 mA output: solid state band gap; Passive output: 10K @ 25°C thermistor (Dwyer curve A) - Range: 0 to 100% RH 4-20 mA loop powered models: 4-20 mA; 0-10 V output models: 0-10 V @ 5 mA max; 0-5 V output models: 0-5 V @ 5 mA max CE Capacitance polymer Designed to meet NEMA 3S (IP54) <1% RH/year RH: ±1%
Dwyer Instruments WHT-322 | Water-resistant humidity/temperature transmitter with sintered filter | 3% accuracy | 0-10 VDC humidity and temperature output - Sensor, RH: ±2% 20 to 80% RH, ±3% @ 10 to 20%, 80 to 90% RH RH: ±0.1% typical - 0.3 oz (8.5 g) - - 4-20 mA loop powered models: 10-35 VDC; 0-10 V output models: 15-35 VDC or 15-29 VAC; 0-5 V output models: 10-35 VDC or 10-29 VAC - 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Electrical: Removable screw terminal block 4 to 20 mA output: solid state band gap; Passive output: 10K @ 25°C thermistor (Dwyer curve A) - Range: 0 to 100% RH 4-20 mA loop powered models: 4-20 mA; 0-10 V output models: 0-10 V @ 5 mA max; 0-5 V output models: 0-5 V @ 5 mA max CE Capacitance polymer Designed to meet NEMA 3S (IP54) <1% RH/year RH: ±1%
Dwyer Instruments WHT-32A | Water-resistant humidity/temperature transmitter with sintered filter | 3% accuracy | 0-10 VDC humidity output and 10K ? Type III | curve A temperature output - 4 to 20 mA Output: ±0.9°F @ 72°F (±0.3°C @ 25°C)
Passive Output: ±0.36°F @ 77°F (±0.2°C @ 25°C)
RH: ±0.1% typical - 0.3 oz (8.5 g) - - 4-20 mA loop powered models: 10-35 VDC; 0-10 V output models: 15-35 VDC or 15-29 VAC; 0-5 V output models: 10-35 VDC or 10-29 VAC - 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Electrical: Removable screw terminal block 4 to 20 mA output: solid state band gap; Passive output: 10K @ 25°C thermistor (Dwyer curve A) - Range: 0 to 100% RH 4-20 mA loop powered models: 4-20 mA; 0-10 V output models: 0-10 V @ 5 mA max; 0-5 V output models: 0-5 V @ 5 mA max CE Capacitance polymer Designed to meet NEMA 3S (IP54) <1% RH/year RH: ±1%
Dwyer Instruments WHT-330 | Water-resistant humidity transmitter with sintered filter | 3% accuracy | 0-5 VDC humidity output - 4 to 20 mA Output: ±0.9°F @ 72°F (±0.3°C @ 25°C)
Passive Output: ±0.36°F @ 77°F (±0.2°C @ 25°C)
RH: ±0.1% typical - 0.3 oz (8.5 g) - - 4-20 mA loop powered models: 10-35 VDC; 0-10 V output models: 15-35 VDC or 15-29 VAC; 0-5 V output models: 10-35 VDC or 10-29 VAC - 15 s -40 to 176°F (-40 to 80°C) Compensated, RH: -4 to 140°F (-20 to 60°C) Electrical: Removable screw terminal block 4 to 20 mA output: solid state band gap; Passive output: 10K @ 25°C thermistor (Dwyer curve A) - Range: 0 to 100% RH 4-20 mA loop powered models: 4-20 mA; 0-10 V output models: 0-10 V @ 5 mA max; 0-5 V output models: 0-5 V @ 5 mA max CE Capacitance polymer Designed to meet NEMA 3S (IP54) <1% RH/year RH: ±1%
Dwyer Instruments WHT-333 | Water-resistant humidity/temperature transmitter with sintered filter | 3% accuracy | 0-5 VDC humidity and temperature output - Sensor, RH: ±2% 20 to 80% RH, ±3% @ 10 to 20%, 80 to 90% RH RH: ±0.1% typical - 0.3 oz (8.5 g) - - 4-20 mA loop powered models: 10-35 VDC; 0-10 V output models: 15-35 VDC or 15-29 VAC; 0-5 V output models: 10-35 VDC or 10-29 VAC - 15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Electrical: Removable screw terminal block 4 to 20 mA output: solid state band gap; Passive output: 10K @ 25°C thermistor (Dwyer curve A) - Range: 0 to 100% RH 4-20 mA loop powered models: 4-20 mA; 0-10 V output models: 0-10 V @ 5 mA max; 0-5 V output models: 0-5 V @ 5 mA max CE Capacitance polymer Designed to meet NEMA 3S (IP54) <1% RH/year RH: ±1%
Dwyer Instruments RHP-2E40 | European Wall Mount Humidity Transmitter with 2% accuracy and universal current / voltage output for RH European Wall Mount Humidity Transmitter RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to 80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C) ±0.1% typical Optional LCD
Switch selectable %RH or dew point, °F/°C
4.4 oz (125 g) - - 4-20 mA loop powered outputs: 10-35 VDC; 0-5/10V outputs: 15-35 VDC or 15-29 VAC RH: 1%
Temperature: 0.1°F (0.1°C)
Dew Point: 1°F (1°C)
8 s - Dew Point: -20 to 140°F (-28.9 to 60°C); 0 to 100°F (-17.8 to 37.8°C); 40 to 90°F (4.4 to 32.3°C); -4 to 140°F (-20 to 60°C) field selectable ranges Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH 4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/ solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output CE Capacitance polymer IP20 <.25% RH/year ±.8%
Dwyer Instruments RHP-2E40-LCD | European Wall Mount Humidity Transmitter with 2% accuracy and universal current / voltage output for RH with LCD European Wall Mount Humidity Transmitter RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to 80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C) ±0.1% typical Optional LCD
Switch selectable %RH or dew point, °F/°C
4.4 oz (125 g) - - 4-20 mA loop powered outputs: 10-35 VDC; 0-5/10V outputs: 15-35 VDC or 15-29 VAC RH: 1%
Temperature: 0.1°F (0.1°C)
Dew Point: 1°F (1°C)
8 s - Dew Point: -20 to 140°F (-28.9 to 60°C); 0 to 100°F (-17.8 to 37.8°C); 40 to 90°F (4.4 to 32.3°C); -4 to 140°F (-20 to 60°C) field selectable ranges Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH 4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/ solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output CE Capacitance polymer IP20 <.25% RH/year ±.8%
Dwyer Instruments RHP-2E44 | European Wall Mount Humidity / Temperature Transmitter with 2% accuracy and universal current / voltage output for RH and Temperature European Wall Mount Humidity / Temperature Transmitter RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to 80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C) ±0.1% typical Optional LCD
Switch selectable %RH or dew point, °F/°C
4.4 oz (125 g) - - 4-20 mA loop powered outputs: 10-35 VDC; 0-5/10V outputs: 15-35 VDC or 15-29 VAC RH: 1%
Temperature: 0.1°F (0.1°C)
Dew Point: 1°F (1°C)
8 s - -40 to 140°F (-40 to 60°C) for thermistor and RTD sensors. -20 to 140°F (-28.9 to 60°C) for solid state band gap temperature sensors Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH 4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/ solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output CE Capacitance polymer IP20 <.25% RH/year ±.8%
Dwyer Instruments RHP-2E44-LCD | European Wall Mount Humidity / Temperature Transmitter with 2% accuracy and universal current / voltage output for RH and Temperature with LCD European Wall Mount Humidity / Temperature Transmitter RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to 80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C) ±0.1% typical Optional LCD
Switch selectable %RH or dew point, °F/°C
4.4 oz (125 g) - - 4-20 mA loop powered outputs: 10-35 VDC; 0-5/10V outputs: 15-35 VDC or 15-29 VAC RH: 1%
Temperature: 0.1°F (0.1°C)
Dew Point: 1°F (1°C)
8 s - Dew Point: -20 to 140°F (-28.9 to 60°C); 0 to 100°F (-17.8 to 37.8°C); 40 to 90°F (4.4 to 32.3°C); -4 to 140°F (-20 to 60°C) field selectable ranges Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH 4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/ solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output CE Capacitance polymer IP20 <.25% RH/year ±.8%
Dwyer Instruments RHP-2E4A | European Wall Mount Humidity / Temperature Transmitter with 2% accuracy and universal current / voltage output for RH and 10K Type III thermistor Temperature Sensor European Wall Mount Humidity / Temperature Transmitter RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to 80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C) ±0.1% typical Optional LCD
Switch selectable %RH or dew point, °F/°C
4.4 oz (125 g) - - 4-20 mA loop powered outputs: 10-35 VDC; 0-5/10V outputs: 15-35 VDC or 15-29 VAC RH: 1%
Temperature: 0.1°F (0.1°C)
Dew Point: 1°F (1°C)
8 s - Compensated: -4 to 140°F (-20 to 60°C) Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH 4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/ solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output CE Capacitance polymer IP20 <.25% RH/year ±.8%
Dwyer Instruments RHP-2E4B | European Wall Mount Humidity / Temperature Transmitter with 2% accuracy and universal current / voltage output for RH and 10K Type II thermistor Temperature Sensor European Wall Mount Humidity / Temperature Transmitter RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to 80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C) ±0.1% typical Optional LCD
Switch selectable %RH or dew point, °F/°C
4.4 oz (125 g) - - 4-20 mA loop powered outputs: 10-35 VDC; 0-5/10V outputs: 15-35 VDC or 15-29 VAC RH: 1%
Temperature: 0.1°F (0.1°C)
Dew Point: 1°F (1°C)
8 s - -40 to 140°F (-40 to 60°C) for thermistor and RTD sensors. -20 to 140°F (-28.9 to 60°C) for solid state band gap temperature sensors Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH 4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/ solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output CE Capacitance polymer IP20 <.25% RH/year ±.8%
Dwyer Instruments RHP-2N40-LCD | North American Wall Mount Humidity Transmitter with 2% accuracy and universal current / voltage output for RH with LCD North American Wall Mount Humidity Transmitter RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to 80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C) ±0.1% typical Optional LCD
Switch selectable %RH or dew point, °F/°C
4.4 oz (125 g) - - 4-20 mA loop powered outputs: 10-35 VDC; 0-5/10V outputs: 15-35 VDC or 15-29 VAC RH: 1%
Temperature: 0.1°F (0.1°C)
Dew Point: 1°F (1°C)
8 s - Dew Point: -20 to 140°F (-28.9 to 60°C); 0 to 100°F (-17.8 to 37.8°C); 40 to 90°F (4.4 to 32.3°C); -4 to 140°F (-20 to 60°C) field selectable ranges Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH 4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/ solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output CE Capacitance polymer IP20 <.25% RH/year ±.8%
Dwyer Instruments RHP-2N44 | North American Wall Mount Humidity / Temperature Transmitter with 2% accuracy and universal current / voltage output for RH and Temperature North American Wall Mount Humidity / Temperature Transmitter RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to 80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C) ±0.1% typical Optional LCD
Switch selectable %RH or dew point, °F/°C
4.4 oz (125 g) - - 4-20 mA loop powered outputs: 10-35 VDC; 0-5/10V outputs: 15-35 VDC or 15-29 VAC RH: 1%
Temperature: 0.1°F (0.1°C)
Dew Point: 1°F (1°C)
8 s - -40 to 140°F (-40 to 60°C) for thermistor and RTD sensors. -20 to 140°F (-28.9 to 60°C) for solid state band gap temperature sensors Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH 4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/ solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output CE Capacitance polymer IP20 <.25% RH/year ±.8%
Dwyer Instruments RHP-2N44-LCD | North American Wall Mount Humidity / Temperature Transmitter with 2% accuracy and universal current / voltage output for RH and Temperature with LCD North American Wall Mount Humidity / Temperature Transmitter RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to 80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C) ±0.1% typical Optional LCD
Switch selectable %RH or dew point, °F/°C
4.4 oz (125 g) - - 4-20 mA loop powered outputs: 10-35 VDC; 0-5/10V outputs: 15-35 VDC or 15-29 VAC RH: 1%
Temperature: 0.1°F (0.1°C)
Dew Point: 1°F (1°C)
8 s - -40 to 140°F (-40 to 60°C) for thermistor and RTD sensors. -20 to 140°F (-28.9 to 60°C) for solid state band gap temperature sensors Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH 4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/ solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output CE Capacitance polymer IP20 <.25% RH/year ±.8%
Dwyer Instruments RHP-2N4A | North American Wall Mount Humidity / Temperature Transmitter with 2% accuracy and universal current / voltage output for RH and 10K Type III thermistor Temperature Sensor North American Wall Mount Humidity / Temperature Transmitter RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to 80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C) ±0.1% typical Optional LCD
Switch selectable %RH or dew point, °F/°C
4.4 oz (125 g) - - 4-20 mA loop powered outputs: 10-35 VDC; 0-5/10V outputs: 15-35 VDC or 15-29 VAC RH: 1%
Temperature: 0.1°F (0.1°C)
Dew Point: 1°F (1°C)
8 s - Compensated: -4 to 140°F (-20 to 60°C) Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH 4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/ solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output CE Capacitance polymer IP20 <.25% RH/year ±.8%
Dwyer Instruments RHP-2N4B | North American Wall Mount Humidity / Temperature Transmitter with 2% accuracy and universal current / voltage output for RH and 10K Type II thermistor Temperature Sensor North American Wall Mount Humidity / Temperature Transmitter RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to 80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C) ±0.1% typical Optional LCD
Switch selectable %RH or dew point, °F/°C
4.4 oz (125 g) - - 4-20 mA loop powered outputs: 10-35 VDC; 0-5/10V outputs: 15-35 VDC or 15-29 VAC RH: 1%
Temperature: 0.1°F (0.1°C)
Dew Point: 1°F (1°C)
8 s - Dew Point: -20 to 140°F (-28.9 to 60°C); 0 to 100°F (-17.8 to 37.8°C); 40 to 90°F (4.4 to 32.3°C); -4 to 140°F (-20 to 60°C) field selectable ranges Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH 4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/ solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output CE Capacitance polymer IP20 <.25% RH/year ±.8%
Dwyer Instruments RHP-3E40 | European Wall Mount Humidity Transmitter with 3% accuracy and universal current / voltage output for RH European Wall Mount Humidity Transmitter RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to 80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C) ±0.1% typical Optional LCD
Switch selectable %RH or dew point, °F/°C
4.4 oz (125 g) - - 4-20 mA loop powered outputs: 10-35 VDC; 0-5/10V outputs: 15-35 VDC or 15-29 VAC RH: 1%
Temperature: 0.1°F (0.1°C)
Dew Point: 1°F (1°C)
8 s - -40 to 140°F (-40 to 60°C) for thermistor and RTD sensors. -20 to 140°F (-28.9 to 60°C) for solid state band gap temperature sensors Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH 4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/ solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output CE Capacitance polymer IP20 <.25% RH/year ±.8%
Dwyer Instruments RHP-3E40-LCD | European Wall Mount Humidity Transmitter with 3% accuracy and universal current / voltage output for RH with LCD European Wall Mount Humidity Transmitter RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to 80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C) ±0.1% typical Optional LCD
Switch selectable %RH or dew point, °F/°C
4.4 oz (125 g) - - 4-20 mA loop powered outputs: 10-35 VDC; 0-5/10V outputs: 15-35 VDC or 15-29 VAC RH: 1%
Temperature: 0.1°F (0.1°C)
Dew Point: 1°F (1°C)
8 s - -40 to 140°F (-40 to 60°C) for thermistor and RTD sensors. -20 to 140°F (-28.9 to 60°C) for solid state band gap temperature sensors Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH 4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/ solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output CE Capacitance polymer IP20 <.25% RH/year ±.8%
Dwyer Instruments RHP-3E44 | European Wall Mount Humidity / Temperature Transmitter with 3% accuracy and universal current / voltage output for RH and Temperature European Wall Mount Humidity / Temperature Transmitter RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to 80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C) ±0.1% typical Optional LCD
Switch selectable %RH or dew point, °F/°C
4.4 oz (125 g) - - 4-20 mA loop powered outputs: 10-35 VDC; 0-5/10V outputs: 15-35 VDC or 15-29 VAC RH: 1%
Temperature: 0.1°F (0.1°C)
Dew Point: 1°F (1°C)
8 s - Dew Point: -20 to 140°F (-28.9 to 60°C); 0 to 100°F (-17.8 to 37.8°C); 40 to 90°F (4.4 to 32.3°C); -4 to 140°F (-20 to 60°C) field selectable ranges Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH 4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/ solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output CE Capacitance polymer IP20 <.25% RH/year ±.8%
Dwyer Instruments RHP-3E44-LCD | European Wall Mount Humidity / Temperature Transmitter with 3% accuracy and universal current / voltage output for RH and Temperature with LCD European Wall Mount Humidity / Temperature Transmitter RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to 80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C) ±0.1% typical Optional LCD
Switch selectable %RH or dew point, °F/°C
4.4 oz (125 g) - - 4-20 mA loop powered outputs: 10-35 VDC; 0-5/10V outputs: 15-35 VDC or 15-29 VAC RH: 1%
Temperature: 0.1°F (0.1°C)
Dew Point: 1°F (1°C)
8 s - Dew Point: -20 to 140°F (-28.9 to 60°C); 0 to 100°F (-17.8 to 37.8°C); 40 to 90°F (4.4 to 32.3°C); -4 to 140°F (-20 to 60°C) field selectable ranges Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH 4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/ solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output CE Capacitance polymer IP20 <.25% RH/year ±.8%
Dwyer Instruments RHPLC-2N11 | North American wall mount humidity/temp transmitter | 2% accuracy | 4-20MA humidity and temperature output - Current/Volt Temp Output: ±0.9°F @ 77°F (±0.5°C @ 25°C) RH: ±0.1% typical - 4.4 oz (125 g) - - 10 to 35 VDC for 4 to 20 mA or 0 to 5 VDC output; 15 to 35 VDC for 0 to 10 VDC output; 10 to 29 VAC for 0 to 5 VDC output; 15 to 29 VAC for 0 to 10 VDC output - 8 s (π63) - Output: -40 to 140°F (-40 to 60°C) Electrical: Screw terminal block - Polycarbonatee Range: 0 to 100% RH - CE - - <0.25% RH/year RH: ±0.8%
Dwyer Instruments RHPLC-2N22 | North American wall mount humidity/temp transmitter | 2% accuracy | 0-10VDC humidity and temperature output - Current/Volt Temp Output: ±0.9°F @ 77°F (±0.5°C @ 25°C) RH: ±0.1% typical - 4.4 oz (125 g) - - 10 to 35 VDC for 4 to 20 mA or 0 to 5 VDC output; 15 to 35 VDC for 0 to 10 VDC output; 10 to 29 VAC for 0 to 5 VDC output; 15 to 29 VAC for 0 to 10 VDC output - 8 s (π63) - Output: -40 to 140°F (-40 to 60°C) Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH - CE - - <0.25% RH/year RH: ±0.8%
Dwyer Instruments RHPLC-3N11 | North American wall mount humidity/temp transmitter | 3% accuracy | 4-20MA humidity and temperature output - RH: ±2% 10 to 90% RH @ 25°C for 2% accuracy units; ±3% 20 to 80% RH @ 25°C for 3% accuracy units RH: ±0.1% typical - 4.4 oz (125 g) - - 10 to 35 VDC for 4 to 20 mA or 0 to 5 VDC output; 15 to 35 VDC for 0 to 10 VDC output; 10 to 29 VAC for 0 to 5 VDC output; 15 to 29 VAC for 0 to 10 VDC output - 8 s (π63) - Output: -40 to 140°F (-40 to 60°C) Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH - CE - - <0.25% RH/year RH: ±0.8%
Dwyer Instruments RHPLC-3N1A | North American wall mount humidity/temp transmitter | 3% accuracy | 4-20MA humidity output | 10k Type III thermistor temperature sensor - Current/Volt Temp Output: ±0.9°F @ 77°F (±0.5°C @ 25°C) RH: ±0.1% typical - 4.4 oz (125 g) - - 10 to 35 VDC for 4 to 20 mA or 0 to 5 VDC output; 15 to 35 VDC for 0 to 10 VDC output; 10 to 29 VAC for 0 to 5 VDC output; 15 to 29 VAC for 0 to 10 VDC output - 8 s (π63) - Output: -40 to 140°F (-40 to 60°C) Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH - CE - - <0.25% RH/year RH: ±0.8%
Dwyer Instruments RHP-3E4A | European Wall Mount Humidity / Temperature Transmitter with 3% accuracy and universal current / voltage output for RH and 10K Type III thermistor Temperature Sensor European Wall Mount Humidity / Temperature Transmitter RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to 80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C) ±0.1% typical Optional LCD
Switch selectable %RH or dew point, °F/°C
4.4 oz (125 g) - - 4-20 mA loop powered outputs: 10-35 VDC; 0-5/10V outputs: 15-35 VDC or 15-29 VAC RH: 1%
Temperature: 0.1°F (0.1°C)
Dew Point: 1°F (1°C)
8 s - Dew Point: -20 to 140°F (-28.9 to 60°C); 0 to 100°F (-17.8 to 37.8°C); 40 to 90°F (4.4 to 32.3°C); -4 to 140°F (-20 to 60°C) field selectable ranges Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH 4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/ solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output CE Capacitance polymer IP20 <.25% RH/year ±.8%
Dwyer Instruments RHP-3E4B | European Wall Mount Humidity / Temperature Transmitter with 3% accuracy and universal current / voltage output for RH and 10K Type II thermistor Temperature Sensor European Wall Mount Humidity / Temperature Transmitter RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to 80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C) ±0.1% typical Optional LCD
Switch selectable %RH or dew point, °F/°C
4.4 oz (125 g) - - 4-20 mA loop powered outputs: 10-35 VDC; 0-5/10V outputs: 15-35 VDC or 15-29 VAC RH: 1%
Temperature: 0.1°F (0.1°C)
Dew Point: 1°F (1°C)
8 s - -40 to 140°F (-40 to 60°C) for thermistor and RTD sensors. -20 to 140°F (-28.9 to 60°C) for solid state band gap temperature sensors Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH 4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/ solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output CE Capacitance polymer IP20 <.25% RH/year ±.8%
Dwyer Instruments RHPLC-3N1B | North American wall mount humidity/temp transmitter | 3% accuracy | 4-20MA humidity output | 10k Type II thermistor temperature sensor - Current/Volt Temp Output: ±0.9°F @ 77°F (±0.5°C @ 25°C) RH: ±0.1% typical - 4.4 oz (125 g) - - 10 to 35 VDC for 4 to 20 mA or 0 to 5 VDC output; 15 to 35 VDC for 0 to 10 VDC output; 10 to 29 VAC for 0 to 5 VDC output; 15 to 29 VAC for 0 to 10 VDC output - 8 s (π63) - Output: -40 to 140°F (-40 to 60°C) Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH - CE - - <0.25% RH/year RH: ±0.8%
Dwyer Instruments RHPLC-3N22 | North American wall mount humidity/temp transmitter | 3% accuracy | 0-10VDC humidity and temperature output - Current/Volt Temp Output: ±0.9°F @ 77°F (±0.5°C @ 25°C) RH: ±0.1% typical - 4.4 oz (125 g) - - 10 to 35 VDC for 4 to 20 mA or 0 to 5 VDC output; 15 to 35 VDC for 0 to 10 VDC output; 10 to 29 VAC for 0 to 5 VDC output; 15 to 29 VAC for 0 to 10 VDC output - 8 s (π63) - Output: -40 to 140°F (-40 to 60°C) Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH - CE - - <0.25% RH/year RH: ±0.8%
Dwyer Instruments RHPLC-3N2A | North American wall mount humidity/temp transmitter | 3% accuracy | 0-10VDC humidity output | 10k Type III thermistor temperature sensor - RH: ±2% 10 to 90% RH @ 25°C for 2% accuracy units; ±3% 20 to 80% RH @ 25°C for 3% accuracy units RH: ±0.1% typical - 4.4 oz (125 g) - - 10 to 35 VDC for 4 to 20 mA or 0 to 5 VDC output; 15 to 35 VDC for 0 to 10 VDC output; 10 to 29 VAC for 0 to 5 VDC output; 15 to 29 VAC for 0 to 10 VDC output - 8 s (π63) - Output: -40 to 140°F (-40 to 60°C) Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH - CE - - <0.25% RH/year RH: ±0.8%
Dwyer Instruments RHPLC-3N2B | North American wall mount humidity/temp transmitter | 3% accuracy | 0-10VDC humidity output | 10k Type II thermistor temperature sensor - Current/Volt Temp Output: ±0.9°F @ 77°F (±0.5°C @ 25°C) RH: ±0.1% typical - 4.4 oz (125 g) - - 10 to 35 VDC for 4 to 20 mA or 0 to 5 VDC output; 15 to 35 VDC for 0 to 10 VDC output; 10 to 29 VAC for 0 to 5 VDC output; 15 to 29 VAC for 0 to 10 VDC output - 8 s (π63) - Output: -40 to 140°F (-40 to 60°C) Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH - CE - - <0.25% RH/year RH: ±0.8%
Dwyer Instruments HHT-EU | Explosion-proof humidity transmitter - ±2% 10 to 90% RH, ±0.9°F at 72°F (±0.3°C at 25°C) ±0.1% typical Optional 2 line alpha numeric, 8 characters/line. Temperature display is °F/°C selectable 2 lb 8 oz (1134 g) - - For intrinsically safe models HHT-IX, 9.5 to 28 VDC. For explosion-proof models HHT-EX, 16.5 to 28 VDC RH: 0.1%
Temperature: 0.1°F (0.1°C)
15 s -40 to 176°F (-40 to 80°C) Compensated: -4 to 140°F (-20 to 60°C) Conduit: 1/2" female NPT Solid state band gap - Range: 0 to 100% RH 4 to 20 mA, 2 channels for humidity/temperature models (loop power on RH) FM, CE Capacitance polymer NEMA 4X (IP66). Models HHT-EX: FM Explosion-proof, Class I Div. 1 Group B, C, D, Class II Div. 1 Group E, F, G, Class III Div. 1; Models HHT-IX: FM Intrinsically Safe, Class I Div. 1 Group A, B, C, D, Class II Div. 1 Group E, F, G, Class III Div. 1 T4 <1% RH/year ±1%
Dwyer Instruments HHT-EU-LCD | Explosion-proof humidity transmitter with LCD display - ±2% 10 to 90% RH, ±0.9°F at 72°F (±0.3°C at 25°C) ±0.1% typical Optional 2 line alpha numeric, 8 characters/line. Temperature display is °F/°C selectable 2 lb 8 oz (1134 g) - - For intrinsically safe models HHT-IX, 9.5 to 28 VDC. For explosion-proof models HHT-EX, 16.5 to 28 VDC RH: 0.1%
Temperature: 0.1°F (0.1°C)
15 s -40 to 176°F (-40 to 80°C) Compensated: -4 to 140°F (-20 to 60°C) Conduit: 1/2" female NPT Solid state band gap - Range: 0 to 100% RH 4 to 20 mA, 2 channels for humidity/temperature models (loop power on RH) FM, CE Capacitance polymer NEMA 4X (IP66). Models HHT-EX: FM Explosion-proof, Class I Div. 1 Group B, C, D, Class II Div. 1 Group E, F, G, Class III Div. 1; Models HHT-IX: FM Intrinsically Safe, Class I Div. 1 Group A, B, C, D, Class II Div. 1 Group E, F, G, Class III Div. 1 T4 <1% RH/year ±1%
Dwyer Instruments HHT-IT | Intrinsically safe humidity/temperature transmitter - ±2% 10 to 90% RH, ±0.9°F at 72°F (±0.3°C at 25°C) ±0.1% typical Optional 2 line alpha numeric, 8 characters/line. Temperature display is °F/°C selectable 2 lb 8 oz (1134 g) - - For intrinsically safe models HHT-IX, 9.5 to 28 VDC. For explosion-proof models HHT-EX, 16.5 to 28 VDC RH: 0.1%
Temperature: 0.1°F (0.1°C)
15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: 1/2" female NPT Solid state band gap - Range: 0 to 100% RH 4 to 20 mA, 2 channels for humidity/temperature models (loop power on RH) FM, CE Capacitance polymer NEMA 4X (IP66). Models HHT-EX: FM Explosion-proof, Class I Div. 1 Group B, C, D, Class II Div. 1 Group E, F, G, Class III Div. 1; Models HHT-IX: FM Intrinsically Safe, Class I Div. 1 Group A, B, C, D, Class II Div. 1 Group E, F, G, Class III Div. 1 T4 <1% RH/year ±1%
Dwyer Instruments HHT-IT-LCD | Intrinsically safe humidity/temperature transmitter with LCD display - ±2% 10 to 90% RH, ±0.9°F at 72°F (±0.3°C at 25°C) ±0.1% typical Optional 2 line alpha numeric, 8 characters/line. Temperature display is °F/°C selectable 2 lb 8 oz (1134 g) - - For intrinsically safe models HHT-IX, 9.5 to 28 VDC. For explosion-proof models HHT-EX, 16.5 to 28 VDC RH: 0.1%
Temperature: 0.1°F (0.1°C)
15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: 1/2" female NPT Solid state band gap - Range: 0 to 100% RH 4 to 20 mA, 2 channels for humidity/temperature models (loop power on RH) FM, CE Capacitance polymer NEMA 4X (IP66). Models HHT-EX: FM Explosion-proof, Class I Div. 1 Group B, C, D, Class II Div. 1 Group E, F, G, Class III Div. 1; Models HHT-IX: FM Intrinsically Safe, Class I Div. 1 Group A, B, C, D, Class II Div. 1 Group E, F, G, Class III Div. 1 T4 <1% RH/year ±1%
Dwyer Instruments HHT-IU | Intrinsically safe humidity transmitter - ±2% 10 to 90% RH, ±0.9°F at 72°F (±0.3°C at 25°C) ±0.1% typical Optional 2 line alpha numeric, 8 characters/line. Temperature display is °F/°C selectable 2 lb 8 oz (1134 g) - - For intrinsically safe models HHT-IX, 9.5 to 28 VDC. For explosion-proof models HHT-EX, 16.5 to 28 VDC RH: 0.1%
Temperature: 0.1°F (0.1°C)
15 s -40 to 176°F (-40 to 80°C) -40 to 140°F (-40 to 60°C) Conduit: 1/2" female NPT Solid state band gap - Range: 0 to 100% RH 4 to 20 mA, 2 channels for humidity/temperature models (loop power on RH) FM, CE Capacitance polymer NEMA 4X (IP66). Models HHT-EX: FM Explosion-proof, Class I Div. 1 Group B, C, D, Class II Div. 1 Group E, F, G, Class III Div. 1; Models HHT-IX: FM Intrinsically Safe, Class I Div. 1 Group A, B, C, D, Class II Div. 1 Group E, F, G, Class III Div. 1 T4 <1% RH/year ±1%
Dwyer Instruments RHP-3N40 | North American Wall Mount Humidity Transmitter with 3% accuracy and universal current / voltage output for RH North American Wall Mount Humidity Transmitter RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to 80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C) ±0.1% typical Optional LCD
Switch selectable %RH or dew point, °F/°C
4.4 oz (125 g) - - 4-20 mA loop powered outputs: 10-35 VDC; 0-5/10V outputs: 15-35 VDC or 15-29 VAC RH: 1%
Temperature: 0.1°F (0.1°C)
Dew Point: 1°F (1°C)
8 s - Dew Point: -20 to 140°F (-28.9 to 60°C); 0 to 100°F (-17.8 to 37.8°C); 40 to 90°F (4.4 to 32.3°C); -4 to 140°F (-20 to 60°C) field selectable ranges Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH 4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/ solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output CE Capacitance polymer IP20 <.25% RH/year ±.8%
Dwyer Instruments RHP-3N40-LCD | North American Wall Mount Humidity Transmitter with 3% accuracy and universal current / voltage output for RH with LCD North American Wall Mount Humidity Transmitter RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to 80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C) ±0.1% typical Optional LCD
Switch selectable %RH or dew point, °F/°C
4.4 oz (125 g) - - 4-20 mA loop powered outputs: 10-35 VDC; 0-5/10V outputs: 15-35 VDC or 15-29 VAC RH: 1%
Temperature: 0.1°F (0.1°C)
Dew Point: 1°F (1°C)
8 s - Dew Point: -20 to 140°F (-28.9 to 60°C); 0 to 100°F (-17.8 to 37.8°C); 40 to 90°F (4.4 to 32.3°C); -4 to 140°F (-20 to 60°C) field selectable ranges Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH 4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/ solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output CE Capacitance polymer IP20 <.25% RH/year ±.8%
Dwyer Instruments RHP-3N44 | North American Wall Mount Humidity / Temperature Transmitter with 3% accuracy and universal current / voltage output for RH and Temperature North American Wall Mount Humidity / Temperature Transmitter RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to 80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C) ±0.1% typical Optional LCD
Switch selectable %RH or dew point, °F/°C
4.4 oz (125 g) - - 4-20 mA loop powered outputs: 10-35 VDC; 0-5/10V outputs: 15-35 VDC or 15-29 VAC RH: 1%
Temperature: 0.1°F (0.1°C)
Dew Point: 1°F (1°C)
8 s - -40 to 140°F (-40 to 60°C) for thermistor and RTD sensors. -20 to 140°F (-28.9 to 60°C) for solid state band gap temperature sensors Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH 4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/ solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output CE Capacitance polymer IP20 <.25% RH/year ±.8%
Dwyer Instruments RHP-3N44-LCD | North American Wall Mount Humidity / Temperature Transmitter with 3% accuracy and universal current / voltage output for RH and Temperature with LCD North American Wall Mount Humidity / Temperature Transmitter RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to 80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C) ±0.1% typical Optional LCD
Switch selectable %RH or dew point, °F/°C
4.4 oz (125 g) - - 4-20 mA loop powered outputs: 10-35 VDC; 0-5/10V outputs: 15-35 VDC or 15-29 VAC RH: 1%
Temperature: 0.1°F (0.1°C)
Dew Point: 1°F (1°C)
8 s - Compensated: -4 to 140°F (-20 to 60°C) Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH 4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/ solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output CE Capacitance polymer IP20 <.25% RH/year ±.8%
Dwyer Instruments RHP-3N4A | North American Wall Mount Humidity / Temperature Transmitter with 3% accuracy and universal current / voltage output for RH and 10K Type III thermistor Temperature Sensor North American Wall Mount Humidity / Temperature Transmitter RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to 80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C) ±0.1% typical Optional LCD
Switch selectable %RH or dew point, °F/°C
4.4 oz (125 g) - - 4-20 mA loop powered outputs: 10-35 VDC; 0-5/10V outputs: 15-35 VDC or 15-29 VAC RH: 1%
Temperature: 0.1°F (0.1°C)
Dew Point: 1°F (1°C)
8 s - -40 to 140°F (-40 to 60°C) for thermistor and RTD sensors. -20 to 140°F (-28.9 to 60°C) for solid state band gap temperature sensors Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH 4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/ solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output CE Capacitance polymer IP20 <.25% RH/year ±.8%
Dwyer Instruments RHP-3N4B | North American Wall Mount Humidity / Temperature Transmitter with 3% accuracy and universal current / voltage output for RH and 10K Type II thermistor Temperature Sensor North American Wall Mount Humidity / Temperature Transmitter RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to 80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C) ±0.1% typical Optional LCD
Switch selectable %RH or dew point, °F/°C
4.4 oz (125 g) - - 4-20 mA loop powered outputs: 10-35 VDC; 0-5/10V outputs: 15-35 VDC or 15-29 VAC RH: 1%
Temperature: 0.1°F (0.1°C)
Dew Point: 1°F (1°C)
8 s - -40 to 140°F (-40 to 60°C) for thermistor and RTD sensors. -20 to 140°F (-28.9 to 60°C) for solid state band gap temperature sensors Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH 4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/ solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output CE Capacitance polymer IP20 <.25% RH/year ±.8%
Dwyer Instruments RHRS | 6 plate solar radiation shield for sintered filter version RH transmitters Radiation Shield - - - 1.00 lbs Dwyer Instruments - - - - - - - - - - - - - - - -
Dwyer Instruments RHRS-10 | 10 plate radiation shield for humidity transmitters Radiation Shield - - - 1.45 lbs Dwyer Instruments - - - - - - - - - - - - - - - -
Dwyer Instruments RHP-2N40 | North American Wall Mount Humidity Transmitter with 2% accuracy and universal current / voltage output for RH North American Wall Mount Humidity Transmitter RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to 80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C) ±0.1% typical Optional LCD
Switch selectable %RH or dew point, °F/°C
4.4 oz (125 g) - - 4-20 mA loop powered outputs: 10-35 VDC; 0-5/10V outputs: 15-35 VDC or 15-29 VAC RH: 1%
Temperature: 0.1°F (0.1°C)
Dew Point: 1°F (1°C)
8 s - -40 to 140°F (-40 to 60°C) for thermistor and RTD sensors. -20 to 140°F (-28.9 to 60°C) for solid state band gap temperature sensors Electrical: Screw terminal block - Polycarbonate Range: 0 to 100% RH 4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/ solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output CE Capacitance polymer IP20 <.25% RH/year ±.8%
BRANDS WE REPRESENT