Conductivity Sensor for High Temperature and Ultrapure Water Applications | SE 600

Brand : Image Brand
Stock Status : Contact us for delivery
Brand : Image Brand
Stock Status : Out of Stock

Part Number : SE 600

A four-electrode conductivity sensor for high purity water, high pressures, and temperatures is the SE 600. The sensor can measure anything from 600 mS/cm to ultrapure water. The sensor is perfect for specific chemistry applications up to 210 °C and 25 bar as well as extremely polluted liquids containing fibrous components because it is constructed of stainless steel and PTFE. Furthermore, all conductivity measurements are precisely corrected for the temperature of the process media thanks to an integrated temperature element.

Quantity:
Provide Calibration Services  
  • Specification
  • Features
  • Catalog
Product Name Material Temperature Cable length: PRESSURE Measuring range Connection
pH Sensor for Water | SE 515 - 23 to 176 °F (-5 to 80 °C) - - - Pg 13.5
ISFET Memosens pH Sensor | SE 547 - 5 to 275°F (-15 to 135°C ) - -2.9 to 145 psi (212 °F) (-0.2 to 10 bar (100 °C)) - -
pH Sensor for Liquids with Suspended Solids | SE 554 - 32 to 266°F (0 to 130°C) - - - -
All-Purpose pH Sensor | SE 555 - 32 to 284°F (0 to 140°C) - - - Pg 13.5
Refillable pH Sensor | SE 557 - 32 to 284°F (0 to 140°C) - - - -
Ultrapure Water pH Sensor | SE 558 - 23 to 212 °F (-5 to +100 °C) - - - -
Refillable Electrolyte Vessel | SE 560 - -4 to 176 °F (-20 to 80 °C) - Unpressurized - -
pH Sensor with PTFE Junction | SE 571 - 23 to 266 °F (-5 to 130 °C) - 0 to 174 psi (0 to 12 bar) - PG 13.5
pH Sensor for High Alkaline Liquids | PL H-93 - 32 to 275°F (0 to 135°C) - 14 to 180 psig (1 to 12 bar) - Screw plug head with Pg 13.5 thread
pH Sensor for Aggressive Liquids | Type 18 - 32 to 284°F (0 to 140°C) 3, 5 and 10 meter with LEMO connector, 212°F (100°C) max. temperature Full vacuum to 215 psig (-1 to 15 bar) - -
Conductivity Sensor for Corrosive Processes | SE 603 Body: PTFE
Electrodes: Platinum
Max. 248 °F (120 °C) Fixed cable, 5 m Max. 174 psi (12 bar) Approx. 0.5 µS/cm … 600 mS/cm -
Coaxial Sensor for Ultrapure Water | SE 604 Cell and electrodes: 1.4571 stainless steel; insulator: PVDF; gaskets: FKM (Viton) Medium: -4 to 248 °F (-20 to +120 °C);
Environment: -13 to 176 °F (-25 to +80 °C)
- Max. 362 psi (25 bar) -4 to 158 °F(-20 to +70 °C);
Max. 145 psi (10 bar) 248 °F (120 °C)
0.0 to 500 µS/cm -
Basic Low-Cost Conductivity Sensor for Water | SE 610 Body: PEI (polyetherimide)
Electrodes: stainless steel, 1.4571
50 to 194 °F (10 to 90 °C) Fixed cable, 5 m 87 psi (6 bar) (at 77 °F (25 °C)) 0.1 to 1000 µS/cm G 1/2″
Coaxial Conductivity Sensor for Heavily Polluted and Fibrous Media | K25 Sensor body: PEEK
Wetted materials: Graphite, Stainless Steel, PEEK
PT 1000 - 145 psi (10 bar) 0 to 1,000 mS/cm -
Coaxial Conductivity Sensor for Low-Conductivity Water | SE 605 Cell and electrodes: stainless steel 1.4435, PEEK insulator Medium: -10°C to 120°C (14°F to 248°F)
Environment: -25°C to 80°C (-13°F to 176°F)
- - 0.04 to 1,000 µS/cm 1″ NPT, 2″ ANSI, Ingold socket, 25 mm, Tri-clamp 1.5″
Coaxial Conductivity Sensor for Low-Conductivity Water | SE 625 Sensor Body: 1.4404 (AISI 316L)
Electrodes: 3.7035 (Titanium Grade 2)
PEEK Insulator
Medium: -10°C to 120°C (14°F to 248°F)
Environment: -25°C to 70°C (-13°F to 158°F)
- - 0 to 1,000 µS/cm 3/4″ NPT
Low Cost Water and Wastewater Conductivity Sensor | SE 615 - 23 to 176 °F (-5 to 80 °C) - Max. 58 psi (4 bar) 10 μS/cm to 20 mS/cm -
Hygienic Conductivity Sensor for Pharmaceutical Applications | SE 620 Cell and electrodes: stainless steel 1.4435, electropolished; 32 to 275 °F (0 to 135 °C) steam-sterilizable - 232 psi (16 bar) at 77 °F (25 °C), 0.05 to 50 µS/cm Clamp DN 25
Corrosion Resistant, Conductivity Sensor | SE 630 Body: PES -4 to +275 °F (-20 to +135 °C) - Max. 232 psi (16 bar) 68 °F (20 °C), 10 µS/cm to 20 mS/cm G 1“
PEEK Toroidal Conductivity Sensor | SE 655 Cell: PEEK; gasket: Viton -4 to +257 °F (-20 to +125 °C) Analog: Fixed Cable, 5 m
Memosens: Fixed Cable, 3 m or 7 m
0 to 290 psi (0 to 20 bar) 0.001 to 2000 mS/cm -
Memosens PFA Toroidal Conductivity Sensor | SE 656 PFA - Fixed cable, 7 m with ferrules - 0 to 2,000 mS/cm -
PP Toroidal Conductivity Sensor | SE 670 PP (polypropylene) 32 … 140 °F (0 … 60 °C) - Max. 145 psi (10 bar) at 35.6°F (20 °C),
max. 87 psi (6 bar) at 140°F (60 °C)
0.02 to 2,000 mS/cm Coupling nut, G 1 1/2“, Replacement sensor for installation in ARF 210/215 or ARD 220
Memosens Hygienic Toroidal Conductivity Sensor for Bio Pharma and F&B | SE 680 PEEK (FDA-certified) 14 to 257 °F(–10 to 125 °C) (302 °F (150 °C) < 60 min.) - 145 psi (10 bar) 176 °F (80 °C),
116 psi (8 bar) 257 °F (125 °C)
Approx. 0.0002 to 2000 mS/cm 2“ Tri-clamp, sensor for installation in ARF 210/215 or ARD 220
Low-cost Oxygen Sensor for Water and Wastewater | SE 715 - 23 … 113 °F
(–5 … 45 °C)
- Max. 43.5 psi (3 bar) - -
Low Maintenance Optical Oxygen Sensor | SE 740 - - - - 4 ppb / 0.05 to 300 % saturation -