Product Name | Length | Temperature | PRESSURE | pH Range |
---|---|---|---|---|
pH Sensor for Water | SE 515 | 120 mm edge length | 23 to 176 °F (-5 to 80 °C) | - | 0 to 14 |
pH Sensor for Liquids with Suspended Solids | SE 554 | 120 or 225 mm | 32 to 266°F (0 to 130°C) | - | 0 to 14 |
All-Purpose pH Sensor | SE 555 | 120, 225, 325, 425 mm | 32 to 284°F (0 to 140°C) | - | 0 to 14 |
Refillable pH Sensor | SE 557 | 120, 225, 325, 425 mm | 32 to 284°F (0 to 140°C) | - | 0 to 14 |
Ultrapure Water pH Sensor | SE 558 | 120 mm / 225 mm | 23 to 212 °F (-5 to +100 °C) | - | 0 to 14 |
Refillable Electrolyte Vessel | SE 560 | - | -4 to 176 °F (-20 to 80 °C) | Unpressurized | 0 to 14 |
pH Sensor with PTFE Junction | SE 571 | 120 mm / 225 mm | 23 to 266 °F (-5 to 130 °C) | 0 to 174 psi (0 to 12 bar) | 0 to 14 |
pH Sensor for High Alkaline Liquids | PL H-93 | 120, 225, & 325 mm | 32 to 275°F (0 to 135°C) | 14 to 180 psig (1 to 12 bar) | 0 to 14 |
pH Sensor for Aggressive Liquids | Type 18 | 5.5″ to 7.5″ (140 to 190 mm) | 32 to 284°F (0 to 140°C) | Full vacuum to 215 psig (-1 to 15 bar) | 3 to 10 pH |
Conductivity Sensor for High Temperature and Ultrapure Water Applications | SE 600 | - | Max. 410 °F (210 °C) | Max. 363 psi (25 bar) | - |
Conductivity Sensor for Corrosive Processes | SE 603 | - | Max. 248 °F (120 °C) | Max. 174 psi (12 bar) | - |
Coaxial Sensor for Ultrapure Water | SE 604 | - | Medium: -4 to 248 °F (-20 to +120 °C); Environment: -13 to 176 °F (-25 to +80 °C) |
Max. 362 psi (25 bar) -4 to 158 °F(-20 to +70 °C); Max. 145 psi (10 bar) 248 °F (120 °C) |
- |
Basic Low-Cost Conductivity Sensor for Water | SE 610 | - | 50 to 194 °F (10 to 90 °C) | 87 psi (6 bar) (at 77 °F (25 °C)) | - |
Coaxial Conductivity Sensor for Heavily Polluted and Fibrous Media | K25 | 120 to 225 mm | PT 1000 | 145 psi (10 bar) | - |
Coaxial Conductivity Sensor for Low-Conductivity Water | SE 605 | - | Medium: -10°C to 120°C (14°F to 248°F) Environment: -25°C to 80°C (-13°F to 176°F) |
- | - |
Coaxial Conductivity Sensor for Low-Conductivity Water | SE 625 | - | Medium: -10°C to 120°C (14°F to 248°F) Environment: -25°C to 70°C (-13°F to 158°F) |
- | - |
Low Cost Water and Wastewater Conductivity Sensor | SE 615 | 120, 225 mm | 23 to 176 °F (-5 to 80 °C) | Max. 58 psi (4 bar) | - |
Hygienic Conductivity Sensor for Pharmaceutical Applications | SE 620 | - | 32 to 275 °F (0 to 135 °C) steam-sterilizable | 232 psi (16 bar) at 77 °F (25 °C), | - |
Corrosion Resistant, Conductivity Sensor | SE 630 | - | -4 to +275 °F (-20 to +135 °C) | Max. 232 psi (16 bar) 68 °F (20 °C), | - |
PEEK Toroidal Conductivity Sensor | SE 655 | - | -4 to +257 °F (-20 to +125 °C) | 0 to 290 psi (0 to 20 bar) | - |
PP Toroidal Conductivity Sensor | SE 670 | - | 32 … 140 °F (0 … 60 °C) | Max. 145 psi (10 bar) at 35.6°F (20 °C), max. 87 psi (6 bar) at 140°F (60 °C) |
- |
Memosens Hygienic Toroidal Conductivity Sensor for Bio Pharma and F&B | SE 680 | - | 14 to 257 °F(–10 to 125 °C) (302 °F (150 °C) < 60 min.) | 145 psi (10 bar) 176 °F (80 °C), 116 psi (8 bar) 257 °F (125 °C) |
- |
Low-cost Oxygen Sensor for Water and Wastewater | SE 715 | 120 mm | 23 … 113 °F (–5 … 45 °C) |
Max. 43.5 psi (3 bar) | - |
General Tech Services L.L.C
Head Office:
P.O. Box: 25898
Sharjah, U A E
Tel: +971 6 5436933
Email: mathews@generaltechuae.com
Website: www.generaltechshop.com