Model Options
Edit these specs to order a different model. Not all combinations are valid. Options compatible with previous selections will be in bold.
Product Name | Display | Weight | Dimensions | Voltage | Operating Temperature | Storage Temperature |
---|---|---|---|---|---|---|
TTi CPX400DP | PowerFlex Dual output 840 watt PSU with USB, RS232, LAN | Dual 4-digit meters, 10mm (0·39”) LED | - | - | 0V to 60V | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
Aim TTi CPX400D | PowerFlex DC Power Supply | Dual 4-digit meters, 10mm (0·39”) LED | - | - | 0V to 60V | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
Aim TTi MX100TP | Combined Output with USB, RS232 and LAN Interfaces | Triple Multi Range 315W | - | 4.9kg | 212 x 130 x 375mm* (WxHxD) Half rack x 3U height. | - | +50C to +400C, 20% to 80% RH | -400C to +700C |
Aim TTi CPX200DP | PowerFlex DC Power Supply Dual Outputs | with USB, RS232 and LAN Interfaces | Dual 4-digit meters, 10mm (0·39”) LED | 5.0kg (11lb) | 210 x 130 mm (½ rack 3U) x 377mm | 0V to 60V | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
Aim TTi MX180TP | DC Power Supply | Triple Output 375 Watt with USB, RS-232 and LAN (LXI) Interfaces | - | 5.0kg (MX180T) 5.1kg (MX180TP) | 212 x 130 x 375mm* (WxHxD) Half rack x 3U height | - | +50C to +400C, 20% to 80% RH | -400C to +700C |
Aim TTi CPX400SP | PowerFlex DC PSUs | Single Output | 420 Watt with Digital Remote Control via USB, RS232 and LAN | Dual 4-digit meters, 10mm (0·39”) LED. | Single - 4.25kg (9.35lb), Dual - 6.3kg (13.9lb) | Single - 107 x 130 (¼ rack 3U) x 398mm Dual - 210 x 130 mm (½ rack 3U) x 377mm (size excludes feet, knobs and terminals). | 0V to 60V | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
Aim TTi CPX200D | PowerFlex Max 60V or 10 A | Twin 180W | Dual 4-digit meters, 10mm (0·39”) LED. | 5.0kg (11lb) | 210 x 130 mm (½ rack 3U) x 377mm (size excludes feet, knobs and terminals). | 0V to 60V | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
TTi MX100QP | DC Power Supply | 4 x 35V/3A 420W, Multi-Range, with USB, RS232, LAN and GPIB Interfaces | - | 7.3kg (MX100Q) 7.5kg (MX100QP) | 320 x 130 x 375mm* (WxHxD) Three quarter rack x 3U height | 110V to 240V AC ± 10%, 50/60Hz. Installation category II | +50C to +400C, 20% to 80% RH | -400C to +700C |
TTi EL183R | Digital voltage and current meters | Single 0-18V/0-3A | - | 4.4kg | Single output models - 140x160x295 mm (WxHxD). Dual and triple output models - 260x160x295 mm (WxHxD). | 230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5°C to +40°C, 20% to 80% RH | -40°C to + 70°C |
Aim TTi EL302RD - Linear Regulated Precision DC Bench 120W | Digital voltage and current meter | 30V/2A | - | 7.5kg | Single output models - 140x160x295 mm (WxHxD). Dual and triple output models - 260x160x295 mm (WxHxD). | 230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5°C to +40°C, 20% to 80% RH | -40°C to + 70°C |
TTi EX354RT | Digital voltage and current meters | Triple 0-35V/0-4A Dual plus 1.5-5V/5A | Dual 4-digit meters, 14mm (0·56”) LED | 4.3kg. | Single output models - 140x160x320 mm (WxHxD). Dual and triple output models - 260x160x320 mm (WxHxD) | - | +5°C to +40°C, 20% to 80% RH | -40°C to + 70°C |
Aim TTi EX4210R Bench DC Power Supply | Mixed-Mode Regulated Precision DC Bench 420W Power Supply 42V/10A | Dual 4-digit meters, 14mm (0·56”) LED | 3.6kg | Single output models - 140x160x320 mm (WxHxD). Dual and triple output models - 260x160x320 mm (WxHxD). | 230V AC ± 10% 50/60Hz; 115V to order | +5°C to +40°C, 20% to 80% RH | -40°C to + 70°C |
Aim TTi LD400P | 360W 80A 80V Electronic DC Loads | USB, RS232 LAN/LXI | 256 x 112 pixel backlit graphic LCD | 5.7 kg | 130mm H (3U) x 212mm W (½ rack) x 435mm D | 110V–120V or 220V–240V AC ±10%, 50/60Hz. Installation Category II. | + 5ºC to + 40ºC, 20% to 80% RH. | – 40ºC to + 70ºC |
Aim TTi PL303QMD - Quad Mode Dual version of PL303 | Dual 4-digit meters, 10mm (0·39”) LED | 4·5kg | 107mm x 131mm (¼ rack 3U) x 288mm | 230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5ºC to +40ºC, 20% to 80% RH | - |
Aim TTi PL601-P | Single 0-60V/0-1.5A USB/RS232/LAN(LXI)/Analog | - | Single output models - 4·9kg; Dual output model - 8.6kg; Triple output model - 12.8kg |
Single output models - 107mm x 131mm (¼ rack 3U) x 315mm, Dual output model - 214mm x 131mm (½ rack 3U) x 288mm Triple output model - 321mm x 131mm (¾ rack 3U) x 288mm (sizes exclude feet, knobs and terminals). |
230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
Aim TTi PLH120 | Higher Voltage Linear Regulated DC Bench Power Supply | Single 0-120V/0-0.75A | - | 4.9kg | - | 230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
TTi PLH250 | Higher Voltage Linear Regulated DC Bench Power Supply | Single 0-250V/0-0.375A | Dual 4-digit meters, 10mm (0·39”) LED. | 4.9kg | PLH models - 107mm x 131mm (¼ rack 3U) x 288mm | - | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
TTi QPX600DP | Analog Power Supplies | Max 80V or 50A RS232/USB/LAN(LXI) | Dual 600W PowerFlex | Large dot-matrix black-on-white backlit LCD. | 9.2kg (20lb). | 350 x 130 x 413mm (WxHxD) (3U height) . | 110V to 240V AC ±10%, 50/60Hz. Installation Category II. | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
TTi MX180T | DC Power Supply | Triple Output 375 Watt Combined Output | - | 4.8 kg | 212 x 130 x 375mm* (WxHxD) Half rack x 3U height. | 110V to 240V AC ± 10%, 50/60Hz. Installation category II | +50C to +400C, 20% to 80% RH | -400C to +700C |
Aim TTi CPX400S | ''PowerFlex'' Max 60V or 20A | Single 420 | Dual 4-digit meters, 10mm (0·39”) LED. | Single - 4.25kg (9.35lb), Dual - 6.3kg (13.9lb) | - | 110 to 240 volts ±10% 50/60Hz. Installation Category II. | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
TTi CPX400SA | PowerFlex DC PSUs with Isolated Analog Remote Control | Single output 420 watt | Dual 4-digit meters, 10mm (0·39”) LED | Single - 4.25kg (9.35lb), Dual - 6.3kg (13.9lb) | Single - 107 x 130 (¼ rack 3U) x 398mm Dual - 210 x 130 mm (½ rack 3U) x 377mm (size excludes feet, knobs and terminals). |
110 to 240 volts ±10% 50/60Hz. Installation Category II. | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
Aim TTi EL155R - Single | Analogue control, 30 to 130 watts, silent cooling | Dual or Triple Outputs, | Dual 4-digit meters, 14mm (0·56”) LED. | 5 kg | Single output models - 140x160x295 mm (WxHxD). Dual and triple output models - 260x160x295 mm (WxHxD). | 230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5°C to +40°C, 20% to 80% RH | -40°C to + 70°C |
Aim TTi EL301R - Linear Regulation | analogue control, 30 to 130 watts, silent cooling | Single, Dual or Triple Outputs, | Dual 4-digit meters, 14mm (0·56”) LED. | 3.4 kg | Single output models - 140x160x295 mm (WxHxD). Dual and triple output models - 260x160x295 mm (WxHxD). | 230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5°C to +40°C, 20% to 80% RH | -40°C to + 70°C |
Aim TTi EL302P - Single | analogue control | Dual or Triple Outputs | 30 to 130 watts, silent cooling | 4 digit meter for voltage and 3 digit meter for current | 9.70 LBS | - | - | - | - |
Aim TTi EL302P-USB | DC 60W Power Supply 30V/2A USB | Bus Programmable | 4 digit meter for voltage and 3 digit meter for current | 4.4 KILOS (9.70 LBS) | - | - | - | - |
Aim TTi EL302R | Precision DC Bench Power Supply | Linear Regulated 60W 30V/2A | Dual 4-digit meters, 14mm (0·56”) LED. | 4.4 kg | - | 230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5°C to +40°C, 20% to 80% RH | -40°C to + 70°C |
Aim TTi EL302RT | DC Bench 130W Power Supply | Linear Regulated Precision 30V/2A | Dual 4-digit meters, 14mm (0·56”) LED. | 7.5 kg | Single output models - 140x160x295 mm (WxHxD). Dual and triple output models - 260x160x295 mm (WxHxD). | 230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5°C to +40°C, 20% to 80% RH | -40°C to + 70°C |
Aim TTi EL303R | Precision DC Bench 90W Power Supply | Linear Regulated 30V/3A | Dual 4-digit meters, 14mm (0·56”) LED. | 5 kg | Single output models - 140x160x295 mm (WxHxD). Dual and triple output models - 260x160x295 mm (WxHxD). | 230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5°C to +40°C, 20% to 80% RH | -40°C to + 70°C |
Aim TTi EL561R | Precision DC Bench 60W Power Supply | Linear Regulated 56V/1.1A | Dual 4-digit meters, 14mm (0·56”) LED. | 4.4 kg | Single output models - 140x160x295 mm (WxHxD). Dual and triple output models - 260x160x295 mm (WxHxD). | 230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5°C to +40°C, 20% to 80% RH | -40°C to + 70°C |
TTi EX1810R | Precision DC Bench 180W Power Supply | EX-R Series Mixed-Mode Regulated 18V/10A | Dual 4-digit meters, 14mm (0·56”) LED. | 3 kg | Single output models - 140x160x320 mm (WxHxD). Dual and triple output models - 260x160x320 mm (WxHxD) | 230V AC ± 10% 50/60Hz; 115V to order. | +5°C to +40°C, 20% to 80% RH | -40°C to + 70°C |
TTi EX2020R | Precision DC Bench | EX-R Series Mixed-Mode Regulated 400W Power Supply 20V/20A | Dual 4-digit meters, 14mm (0·56”) LED. | 3.6 kg | Single output models - 140x160x320 mm (WxHxD). Dual and triple output models - 260x160x320 mm (WxHxD). | 230V AC ± 10% 50/60Hz; 115V to order. | +5°C to +40°C, 20% to 80% RH | -40°C to + 70°C |
Aim TTi EX354RD - EX-R Series | Precision DC Bench 280W Power Supply | Mixed-Mode Regulated 35V/4A Dual | Dual 4-digit meters, 14mm (0·56”) LED. | 4.3 kg | Single output models - 140x160x320 mm (WxHxD). Dual and triple output models - 260x160x320 mm (WxHxD) | 110V to 240V 50/60Hz (universal input) | +5°C to +40°C, 20% to 80% RH | -40°C to + 70°C |
Aim TTi EX355P | DC Power Supply 35V/5A | EX-P Series Bus Programmable 175W | 4 digit meter for voltage and 3 digit meter for current | - | - | - | - | - |
TTi EX355P-USB - EX-P Series | DC Power Supply | Bus Programmable 175W35V/5A | 4 digit meter for voltage and 3 digit meter for current | - | - | - | - | - |
Aim TTi EX355R EX-R Series | DC Bench 175W Power Supply | Mixed-Mode Regulated Precision 35V/5A | - | 3 kg | Single output models - 140x160x320 mm (WxHxD). Dual and triple output models - 260x160x320 mm (WxHxD). | 230V AC ± 10% 50/60Hz; 115V to order. | +5°C to +40°C, 20% to 80% RH | -40°C to + 70°C |
Aim TTi EX752M DC Bench 300W Power Supply | Mixed-Mode Regulated Precision 2X75V/2A | 3 digit meters for voltage and current; (4 digit on second voltmeter to maintain resolution above 100V | - | Single output models - 140x160x320 mm (WxHxD). Dual and triple output models - 260x160x320 mm (WxHxD) | 230V AC ± 10% 50/60Hz; 115V to order. | +5°C to +40°C, 20% to 80% RH | -40°C to + 70°C |
Aim TTi LD400 - Electronic DC Load | with or without Remote Interfaces | 80V, 80A, 400W | - | 5.7 LBS | - | - | - | - |
TTi LDH400P | 500V, 16A, 400W | Electronic DC Load | - | 12.56 LBS | - | - | - | - |
Aim TTi MX100Q | DC Power Supply | 4 x 35V/3A 420W | Multi-Range | - | 7.3kg | 320 x 130 x 375mm* (WxHxD) Three quarter rack x 3U height | 110V to 240V AC ± 10%, 50/60Hz. Installation category II | +50C to +400C, 20% to 80% RH | -400C to +700C |
Aim TTi MX100T | Combined Output | Triple Multi Range 315W | DC Power Supply | - | 4.8kg | 212 x 130 x 375mm* (WxHxD) Half rack x 3U height. | 110V to 240V AC ± 10%, 50/60Hz. Installation category II | +50C to +400C, 20% to 80% RH | -400C to +700C |
TTi PL068 | Single Precision Bench System DC Power Supply | 6V/8A | Dual 4-digit meters, 10mm (0·39”) LED | 4·5kg | 107mm x 131mm (¼ rack 3U) x 288mm | 230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
Aim TTi PL068-P | Bench System DC Power Supply | Single 0-6V/0-8A USB/RS232/LAN(LXI)/Analog | - | Single output models - 4·9kg; Dual output model - 8.6kg; Triple output model - 12.8kg |
Single output models - 107mm x 131mm (¼ rack 3U) x 315mm, Dual output model - 214mm x 131mm (½ rack 3U) x 288mm Triple output model - 321mm x 131mm (¾ rack 3U) x 288mm (sizes exclude feet, knobs and terminals). |
230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
Aim TTi PL068-P (G) Single | 0-6V/0-8A USB/RS232/LAN(LXI)/Analog/GPIB | - | Single output models - 4·9kg; Dual output model - 8.6kg; Triple output model - 12.8kg |
Single output models - 107mm x 131mm (¼ rack 3U) x 315mm, Dual output model - 214mm x 131mm (½ rack 3U) x 288mm Triple output model - 321mm x 131mm (¾ rack 3U) x 288mm (sizes exclude feet, knobs and terminals). |
230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
TTi PL155 | Linear Regulated | Single Precision DC Power Supply | Bench/System with Smart Analog Controls, , 15V/5A | Dual 4-digit meters, 10mm (0·39”) LED | 4·5kg | 107mm x 131mm (¼ rack 3U) x 288mm | 230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
TTi PL155-P | Bench System DC Power Supply | Single 0-15V/0-5A USB/RS232/LAN(LXI)/Analog | - | Single output models - 4·9kg; Dual output model - 8.6kg; Triple output model - 12.8kg |
Single output models - 107mm x 131mm (¼ rack 3U) x 315mm, Dual output model - 214mm x 131mm (½ rack 3U) x 288mm Triple output model - 321mm x 131mm (¾ rack 3U) x 288mm (sizes exclude feet, knobs and terminals). |
230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
TTi PL155-P(G) | Bench System DC Power Supply | Single 0-15V/0-5A USB/RS232/LAN(LXI)/Analog/GPIB | - | Single output models - 4·9kg; Dual output model - 8.6kg; Triple output model - 12.8kg |
Single output models - 107mm x 131mm (¼ rack 3U) x 315mm, Dual output model - 214mm x 131mm (½ rack 3U) x 288mm Triple output model - 321mm x 131mm (¾ rack 3U) x 288mm (sizes exclude feet, knobs and terminals). |
230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
Aim TTi PL303 | DC Bench Power Supplies | Single Precision , 0-30V/0-3A | - | 4·5kg | 107mm x 131mm (¼ rack 3U) x 288mm | 230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
TTi PL303-P(G) | Bench System DC Power Supply | Single 0-30V/0-3A USB/RS232/LAN(LXI)/Analog/GPIB | - | Single output models - 4·9kg; Dual output model - 8.6kg; Triple output model - 12.8kg |
Single output models - 107mm x 131mm (¼ rack 3U) x 315mm, Dual output model - 214mm x 131mm (½ rack 3U) x 288mm Triple output model - 321mm x 131mm (¾ rack 3U) x 288mm (sizes exclude feet, knobs and terminals). |
230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
TTi PL303QMD-P | Bench System DC Power Supply | Dual 0-30V/0-3A USB/RS232/LAN(LXI) | - | Single output models - 4·9kg; Dual output model - 8.6kg; Triple output model - 12.8kg |
Single output models - 107mm x 131mm (¼ rack 3U) x 315mm, Dual output model - 214mm x 131mm (½ rack 3U) x 288mm Triple output model - 321mm x 131mm (¾ rack 3U) x 288mm (sizes exclude feet, knobs and terminals). |
230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
Aim TTi PL303QMD-P(G) | Linear Regulated DC Power Supply | Bench/System | with Smart Analog Controls | - | Single output models - 4·9kg; Dual output model - 8.6kg; Triple output model - 12.8kg |
Single output models - 107mm x 131mm (¼ rack 3U) x 315mm, Dual output model - 214mm x 131mm (½ rack 3U) x 288mm Triple output model - 321mm x 131mm (¾ rack 3U) x 288mm (sizes exclude feet, knobs and terminals). |
230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
Aim TTi PL303QMT | DC Bench Power Supplies | Triple Precision | 0-30V/0-3A,0-6V/0-8A | Dual 4-digit meters, 10mm (0·39”) LED | 4·5kg | 107mm x 131mm (¼ rack 3U) x 288mm | 230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
Aim TTi PL303QMT-P | Bench System DC Power Supply | Triple 0-30V/0-3A,0-6V/0-8A USB/RS232/LAN(LXI) | - | Single output models - 4·9kg; Dual output model - 8.6kg; Triple output model - 12.8kg |
Single output models - 107mm x 131mm (¼ rack 3U) x 315mm, Dual output model - 214mm x 131mm (½ rack 3U) x 288mm Triple output model - 321mm x 131mm (¾ rack 3U) x 288mm (sizes exclude feet, knobs and terminals). |
230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
TTi PL303QMT-P(G) | Bench System DC Power Supply | Triple 0-30V/0-3A,0-6V/0-8A USB/RS232/LAN(LXI)/GPIB | - | Single output models - 4·9kg; Dual output model - 8.6kg; Triple output model - 12.8kg |
Single output models - 107mm x 131mm (¼ rack 3U) x 315mm, Dual output model - 214mm x 131mm (½ rack 3U) x 288mm Triple output model - 321mm x 131mm (¾ rack 3U) x 288mm (sizes exclude feet, knobs and terminals). |
230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
TTi PL601 | DC Bench Power Supplies | Single Precision | 0-60V/0-1.5A | Dual 4-digit meters, 10mm (0·39”) LED | 4·5kg | 107mm x 131mm (¼ rack 3U) x 288mm | 230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
TTi PL601-P(G) | Bench System DC Power Supply | Single 0-60V/0-1.5A USB/RS232/LAN(LXI)/Analog/GPIB | - | Single output models - 4·9kg; Dual output model - 8.6kg; Triple output model - 12.8kg |
Single output models - 107mm x 131mm (¼ rack 3U) x 315mm, Dual output model - 214mm x 131mm (½ rack 3U) x 288mm Triple output model - 321mm x 131mm (¾ rack 3U) x 288mm (sizes exclude feet, knobs and terminals). |
230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
TTi PLH250-P | DC Power Supply | Single Higher Voltage | 0-250V/0-0.375A, Analog | Dual 4-digit meters, 10mm (0·39”) LED | 5.0kg | 107mm x 131mm (¼ rack 3U) x 315mm | 230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
TTi PLH250-P(G) | DC Power Supply | Single Higher Voltage | 0.375A, USB/RS232/LAN/GPI | Dual 4-digit meters, 10mm (0·39”) LED | 5.0kg | 107mm x 131mm (¼ rack 3U) x 315mm | 230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
TTi QL355 SII | Linear Regulated Precision Power Supply | Single 0-35V/0-5A | Dual digital displays per output using 14mm (0.56”) high brightness LEDs. 5 digits for voltage, 4 digits for current. Update rate 4 per second. | Single - 5.5kg (12lb), Triple - 10.5kg (23lb) | Single - 140 x 160 (1/3 rack, 4U) x 290mm Triple - 280 x 160 (2/3 rack, 4U) x 290mm (size excludes feet, knobs and terminals). |
230V AC or 115V AC ± 10%, 50/60Hz Installation Category II. | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
TTi QL355T SII | Linear Regulated Precision Power Supply | Dual QL355 plus 1-6V/3A | Dual digital displays per output using 14mm (0.56”) high brightness LEDs. 5 digits for voltage, 4 digits for current. Update rate 4 per second. | Single - 5.5kg (12lb), Triple - 10.5kg (23lb) |
Single - 140 x 160 (1/3 rack, 4U) x 290mm Triple - 280 x 160 (2/3 rack, 4U) x 290mm (size excludes feet, knobs and terminals). |
230V AC or 115V AC ± 10%, 50/60Hz Installation Category II. | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
TTi QL564 SII | Linear Regulated Precision Power Supply | Single 0-56V/0-4A | Dual digital displays per output using 14mm (0.56”) high brightness LEDs. 5 digits for voltage, 4 digits for current. Update rate 4 per second. | Single - 5.5kg (12lb), Triple - 10.5kg (23lb) |
Single - 140 x 160 (1/3 rack, 4U) x 290mm Triple - 280 x 160 (2/3 rack, 4U) x 290mm (size excludes feet, knobs and terminals). |
230V AC or 115V AC ± 10%, 50/60Hz Installation Category II. | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
Aim TTi QL564P SII | Linear Regulated Precision Power Supply | Dual digital displays per output using 14mm (0.56”) high brightness LEDs. 5 digits for voltage, 4 digits for current. Update rate 4 per second. | Single - 5.5kg (12lb), Triple - 10.5kg (23lb) |
Single - 140 x 160 (1/3 rack, 4U) x 290mm Triple - 280 x 160 (2/3 rack, 4U) x 290mm (size excludes feet, knobs and terminals). |
230V AC or 115V AC ± 10%, 50/60Hz Installation Category II | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
TTi QL564T SII | Advanced dc power supply | Dual QL564 plus 1-6V/3A Linear Regulated Precision Power Supply | Dual digital displays per output using 14mm (0.56”) high brightness LEDs. 5 digits for voltage, 4 digits for current. Update rate 4 per second. | Single - 5.5kg (12lb), Triple - 10.5kg (23lb) | Single - 140 x 160 (1/3 rack, 4U) x 290mm Triple - 280 x 160 (2/3 rack, 4U) x 290mm (size excludes feet, knobs and terminals). |
230V AC or 115V AC ± 10%, 50/60Hz Installation Category II. | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
TTi QL564TP SII | Linear Regulated Precision Power Supply | Dual QL564 plus 1-6V/3A LXI/USB/RS232/GPIB | Dual digital displays per output using 14mm (0.56”) high brightness LEDs. 5 digits for voltage, 4 digits for current. Update rate 4 per second. | Single - 5.5kg (12lb), Triple - 10.5kg (23lb) |
Single - 140 x 160 (1/3 rack, 4U) x 290mm Triple - 280 x 160 (2/3 rack, 4U) x 290mm (size excludes feet, knobs and terminals). |
230V AC or 115V AC ± 10%, 50/60Hz Installation Category II. | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
TTi QPX600D | Analog Power Supplies | Dual 600W 'PowerFlex' Max 80V or 50A / | Large dot-matrix black-on-white backlit LCD. | 9.2kg (20lb). | 350 x 130 x 413mm (WxHxD) (3U height) . | 110V to 240V AC ±10%, 50/60Hz. Installation Category II. | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
TTi TSX 1820P | silent DC Power Supply with mixed-mode regulation | Bench/System Lxi Single 0-18V/0-20A, RS232/GPIB | Dual 4 digit meters with 12·5mm (0.5")LEDs. Reading rate 4Hz | 4.5kg (TSX versions) 5.0kg (TSX-P versions) | 200 x 140 x 385mm (WxHxD); Half rack width x 3U height. | 110V – 240V AC ± 10%, 50/60Hz. Installation Category II. | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
TTi TSX 3510P | mixed-mode regulation | Bench/System | Silent DC Power Supply | Lxi Single 0-35V/0-10A, RS232/GPIB | Dual 4 digit meters with 12·5mm (0.5")LEDs. Reading rate 4Hz | - | 200 x 140 x 385mm (WxHxD); Half rack width x 3U height. | 110V – 240V AC ± 10%, 50/60Hz. Installation Category II. | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
Aim TTi TSX3510 | High Performance DC Bench Power Supply | High Power Single 0-35V/0-10A, | Separate 4 digit meters for voltage and current with 12.5mm (0.5") LED displays. | 5 kg | 210 x 130 x 350mm (WxHxD) (half rack width x 3U height). |
220V to 240 volts ± 10% or 110 to 120 volts ± 10%, 47 to 63Hz. Installation Category II. | +5ºC to +40ºC, 20% to 80% RH | -40ºC to + 70ºC |
Portable Power Supply | 1.5 Hours of Continuous Operation for AC and AC/DC Yokes | - | - | - | 230VAC | - | - |
Replacement Battery for Thermal Imaging Camera R2170 | - | 5.5oz (155g) | 4.3 x 2.6 x 1.8" (108 x 65 x 45mm) | - | 32 to 122°F (0 to 50°C) | 14 to 140°F (-10 to 60°C) |