Whatsapp

Model Options

Edit these specs to order a different model. Not all combinations are valid. Options compatible with previous selections will be in bold.

95 % non-condensing at 40 °C / 104 °F - EN61800-2(3k3)
With De-Rate -10 °C to 60 °C (14 °F to 140 °F)
Without De-Rate -10 °C to 40 °C (14 °F to 104 °F)
-40 °C to 60 °C (-40 °F to 140 °F)
IP20
Output frequency resolution: 0.1 Hz <br>Analogue input 1: 11 bit <br>Analogue input 2: 11 bit <br>Current: The resolution of the current feedback is 10 bit plus sign
Output frequency resolution: 0.1 Hz <br>Analogue input 1: 11 bit <br>Analogue input 2: 11 bit<br> Current: The resolution of the current feedback is 10 bit plus sign
Output frequency resolution: 0.1 Hz <br>Analogue input 1: 11 bit<br> Analogue input 2: 11 bit <br>Current: The resolution of the current feedback is 10 bit plus sign
Output frequency resolution: 0.1 Hz <br>Analogue input 1: 11 bit<br> Analogue input 2: 11 bit<br> Current: The resolution of the current feedback is 10 bit plus sign
Output frequency resolution: 0.1 Hz<br> Analogue input 1: 11 bit <br>Analogue input 2: 11 bit <br>Current: The resolution of the current feedback is 10 bit plus sign
1 x Relay (single pole, double throw relay)
2 x Analogue input <br>Possible settings: 0-10 V, 0-20 mA, 4-20 mA (No Alarm), 4-20 mA (Alarm), 4-20 mA (Error), Digital
2 x Analogue input Possible settings: 0-10 V, 0-20 mA, 4-20 mA (No Alarm), 4-20 mA (Alarm), 4-20 mA (Error), Digital
2 x Analogue input<br> Possible settings: 0-10 V, 0-20 mA, 4-20 mA (No Alarm), 4-20 mA (Alarm), 4-20 mA (Error), Digital
4 x Digital inputs (1 frequency input) 1 x Digital input / output (can be used as a frequency or PWM output to represent analog value)
Digital <br>4 x Digital inputs (1 frequency input) 1 x Digital input / output (can be used as a frequency or PWM output to represent analog value)
Digital<br> 4 x Digital inputs (1 frequency input) 1 x Digital input / output (can be used as a frequency or PWM output to represent analog value)
Digital<br>4 x Digital inputs (1 frequency input) 1 x Digital input / output (can be used as a frequency or PWM output to represent analog value)
1 x Analogue output <br>Possible settings: 0-10 V, 0-20 mA, 4-20 mA
1 x Analogue output Possible settings: 0-10 V, 0-20 mA, 4-20 mA
1 x Analogue output<br> Possible settings: 0-10 V, 0-20 mA, 4-20 mA
RJ45 for Modbus RTU, <br>NFC for app interface
RJ45 for Modbus RTU,<br> NFC for app interface
Supply Frequency Range 45 to 66 Hz<br>Output Frequency/Speed Range 0 to 300 Hz <br>Switching Frequency 4 kHz or 12 kHz
Supply Frequency Range 45 to 66 Hz<br>Output Frequency/Speed Range 0 to 300 Hz<br>Switching Frequency 4 kHz or 12 kHz
Supply Frequency Range 45 to 66 Hz<br>Output Frequency/Speed Range 0 to 300 Hz<br>Switching Frequency 4 kHz or 12 kHz<br>
0.18 to 4 kW / 0.25 to 5 hp
product

Control Techniques S100-03D13-0A0000 | COMMANDER S AC DRIVE | 1/3 PHASE | MAX CONTINUOUS 10.6A Z |MOTOR SHAFT 2.2 kW | 3 HP, 200/240VAC +/- 10%

Brand : Image Brand
Stock Status : Contact us for delivery
Brand : Image Brand
Stock Status : Out of Stock

Part Number : S100-03D13-0A0000

The Commander S is the first drive to use NFC technology, and its streamlined, curved shape optimizes component layout for a tiny footprint and convenient terminal access. Installation is made simple by the click-on/click-off DIN rail mount, and the Commander S has several special features that are intended to save the customer money, time, and effort. The Marshal app, which is available for iOS and Android, is the ground-breaking method of interacting with the drive that covers commissioning, monitoring, diagnostics, and support with NFC technology. The Commander S is the first drive to come with an app interface as a standard feature.

Quantity:
Provide Calibration Services  
  • Specification
  • Features
  • Catalog
BRANDS WE REPRESENT