Model Options

Edit these specs to order a different model. Not all combinations are valid. Options compatible with previous selections will be in bold.

5.6 oz (158.8 g)
16 to 35 VDC / 19 to 28 VAC
Limits: 10 to 95% RH (non-condensing)
2 minutes for 99% step change
±40 PPM + 3% of reading (CO2)
±2% (RH)
Current: 4 to 20 mA (max 500 Ω)
Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω)
Relay: SPST NO 2A @ 30 VDC
RTD or thermistor per r-t curves (depending on model)
Average: 2 watts
Peak: 3.75 watts
32 to 122°F (0 to 50°C)
Dependence: 0.13% of reading per mm of Hg
16 PPM
Dependence: ±8 ppm/ °C at 1100 PPM
Dwyer Instruments
Single-beam, dual-wavelength NDIR
Carbon Dioxide, Relative Humidity and Temperature Transmitters
Duct mount: NEMA 4X (IP66) for housing only
Wall mount: IP20
product

Dwyer Instruments CDTR-2D4E4 | Carbon Dioxide/RH/Temperature Transmitter | 2000 ppm CO2 range | Duct mount | 4 to 20 mA/0 to (5 or 10) VDC CO2 output | RH outputs & Pt1000 O RTD temperature output

Brand : Image Brand
Stock Status : Contact us for delivery
Brand : Image Brand
Stock Status : Out of Stock

Part Number : CDTR-2D4E4

The number of sensors installed on a wall or in a duct is decreased with the Carbon Dioxide, Relative Humidity, and Temperature Transmitters, Series CDTR, Model CDTR-2D4E4. System integrators can cut installation time and material costs by integrating temperature, RH, and CO2 into a single device. A single beam dual wavelength non-dispersive infrared (NDIR) sensor is employed, similar to our well-liked Series CDT Carbon Dioxide Transmitter, to automatically correct the measurement against light source aging effects in both occupied* and unoccupied buildings. The Series CDTR also has the capability to field calibrate the sensor and adjust digitally for barometric pressure, ensuring optimal accuracy. Users can choose the transmitter output to be 4 to 20 mA, 0 to 5 VDC, or 0 to 10 VDC to work with almost any building management controller thanks to universal outputs for both carbon dioxide and relative humidity. For a temperature output, an RTD sensor or passive thermistor can also be supplied. The Series CDTR wall mount versions can be supplied with an integrated LCD display for applications that need visual indication. Temperature only, relative humidity only, CO2 only, CO2 and humidity, or CO2 and temperature are the possible configurations for the display. All transmitter variants come with push buttons that allow users to access the menu structure. An internal jumper option can be used to lock out button operation to avoid tampering.